Coronary perfusion pressure as a determinant of ventricular performance
Nenhuma Miniatura disponível
Data
1980-12-01
Autores
Tucci, P. J.
Spadaro, J.
Ciogna, A. C.
Bregagnollo, E. A.
Título da Revista
ISSN da Revista
Título de Volume
Editor
Resumo
The results observed in this work support the view that coronary perfusion pressure affects ventricular performance independently of metabolic effects; a mechanism operating in beat-to-beat regulation is proposed.
Descrição
Palavras-chave
animal experiment, coronary artery blood flow, dog, heart, heart ventricle contraction, isolated heart, Animal, Blood Pressure, Coronary Vessels, Dogs, Heart, In Vitro, Perfusion, Support, Non-U.S. Gov't
Como citar