New methodology for pH measurements in fuel ethanol using glass electrode

Nenhuma Miniatura disponível

Data

2011-01-01

Autores

Da Silva, Ricardo Moutinho [UNESP]
Borges, Paulo Paschoal
Serta Fraga, Isabel Cristina
Stradiotto, Nelson Ramos [UNESP]

Título da Revista

ISSN da Revista

Título de Volume

Editor

Resumo

Studies carried out with glass electrode in anhydrous ethanol and ethanol-water solutions for measuring pH values have shown that this parameter depends on the solution composition, the contact time with the solution, the utilized temperature, and the type of electrolyte used. It was also observed that the glass electrode behavior in an acid medium differs from an alkaline medium. These studies provided correction factors for pH values from 2 to 12, allowing the realization of proper measurements of the hydrogen ionic activity in the ethanol-water and anhydrous ethanol solutions. However, these correction factors could not be applied to the fuel ethanol. Alternatively, a new method was developed for the correction of the pH values, which can be applied in hydrous and anhydrous fuel ethanol samples. Copyright © 2011 by ASTM International.

Descrição

Palavras-chave

Ethanol-water solutions, Fuel ethanol, Glass electrode, pH, Acid medium, Alkaline medium, Anhydrous ethanol, Contact time, Correction factors, Ethanol-water, Glass electrodes, Ionic activity, Measuring pH, PH measurements, pH value, Solution composition, Electrodes, Fuels, Glass, pH effects, Ethanol

Como citar

Journal of ASTM International, v. 8, n. 1, 2011.