Publicação: Sizing PZT Transducers in Impedance-Based Structural Health Monitoring
Carregando...
Data
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Institute of Electrical and Electronics Engineers (IEEE)
Tipo
Artigo
Direito de acesso
Acesso restrito
Resumo
A theoretical and experimental analysis regarding the correct size of PZT (Lead Zirconate Titanate) transducers used in structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique is presented. Tests were carried out on aluminum structures using 5A and 5H PZT patches of various sizes. The results show that the sensitivity of SHM systems for damage detection can be optimized if the transducers are correctly sized according to the proposed procedure.
Descrição
Palavras-chave
Electromechanical impedance, PZT ceramics, structural engineering, structural health monitoring (SHM)