Wavespeed measurement in buried water distribution pipes and its significance in leak location

dc.contributor.authorBrennan, Michael [UNESP]
dc.contributor.authorDe Almeida, Fabricio
dc.contributor.authorJoseph, Philip
dc.contributor.authorDray, Simon
dc.contributor.authorWhitfield, Stuart
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversity of Southampton
dc.contributor.institutionHydrosave Ltd.
dc.contributor.institutionSouth Staffs Water plc
dc.date.accessioned2014-05-27T11:30:42Z
dc.date.available2014-05-27T11:30:42Z
dc.date.issued2013-09-16
dc.description.abstractTo determine the location of leaks in buried water pipes, acoustic methods are often used. These have proven to be very effective in metallic pipes but have been problematic in modern plastic pipes. In this paper the reason why this is so is discussed together with some measurements that were made on a bespoke test rig built by South Staffs Water plc. A particular problem is the estimate of the wavespeed. Tables are frequently used for this purpose, but these are often inaccurate and this means that a leak cannot be located accurately. An in-situ measure of the wavespeed is thus preferable. In this paper it is shown that there are significant issues in obtaining an accurate estimate of the wavespeed when a leak is present in the system. A method is proposed that overcomes some of these problems, which is discussed and is demonstrated using some data from the bespoke test-rig. © (2013) Trans Tech Publications.en
dc.description.affiliationDepartment of Mechanical Engineering UNESP, Ilha Solteira, 15385-000, SP
dc.description.affiliationInstitute of Sound and Vibration Research University of Southampton, SO17 1BJ
dc.description.affiliationHydrosave Ltd., Swallow Court, Venture Park, Kettering, NN15 6XX
dc.description.affiliationSouth Staffs Water plc, Green Lane, Walsall, WS2 7PD
dc.description.affiliationUnespDepartment of Mechanical Engineering UNESP, Ilha Solteira, 15385-000, SP
dc.format.extent1202-1209
dc.identifierhttp://dx.doi.org/10.4028/www.scientific.net/KEM.569-570.1202
dc.identifier.citationKey Engineering Materials, v. 569-570, p. 1202-1209.
dc.identifier.doi10.4028/www.scientific.net/KEM.569-570.1202
dc.identifier.issn1013-9826
dc.identifier.scopus2-s2.0-84883692200
dc.identifier.urihttp://hdl.handle.net/11449/76570
dc.identifier.wosWOS:000326409000150
dc.language.isoeng
dc.relation.ispartofKey Engineering Materials
dc.relation.ispartofsjr0,180
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectBuried plastic pipes
dc.subjectLeak detection
dc.subjectWavespeed estimate
dc.subjectAcoustic method
dc.subjectLeak locations
dc.subjectMetallic pipes
dc.subjectTest rigs
dc.subjectWater distribution pipes
dc.subjectWater pipes
dc.subjectWavespeed
dc.subjectDamage detection
dc.subjectPlastic pipe
dc.subjectWater pipelines
dc.subjectEstimation
dc.titleWavespeed measurement in buried water distribution pipes and its significance in leak locationen