Simultaneous Determination of Two Groups of Elements in Milk by Electrothermal Atomic Absorption Spectrometry: Evaluation of Ruthenium Modifiers

dc.contributor.authorFreschi, Gian Paulo G. [UNESP]
dc.contributor.authorFreschi, Carolina D. [UNESP]
dc.contributor.authorGomes Neto, José Anchieta [UNESP]
dc.contributor.institutionUniversidade Federal da Grande Dourados (UFGD)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T14:19:29Z
dc.date.available2014-05-20T14:19:29Z
dc.date.issued2009-09-01
dc.description.abstractDifferent kinds of ruthenium coatings are proposed as chemical modifiers for the simultaneous determination of two groups of elements: first, the more Volatile elements Such as As, Bi, Pb, Sb, and Se and, second, the elements Co, Cr, Cu, Fe, and Mn in milk samples by electrothermal atomic absorption spectrometry. Uncoated and coated platforms tube with Ru modifiers and co-injection of Pd+Mg were Studied. Milk samples were 1 + 9 diluted in 1.0% (v/v) HNO(3) an injected into the tube. Very long tube lifetimes were obtained for the two groups with around 750 cycles for the direct determination of the diluted milk sample. Platforms, pretreated with W-Ru, were selected for the first group and pretreated platforms with W plus RuCl(3) were selected for the second group. Calibration by matrix matching and analytical curves in the 5.0 - 20.0 mu g L(-1) range with good linear correlation coefficients were obtained. Relative standard deviations were 7.2% and the calculated characteristic masses were between 7.2 pg and 89.1 pg. The limits of detection obtained for undiluted milk samples were as follows:For Group I elements:32 mu g L(-1) for As; 36 mu g L(-1) for Bi; 29 mu g L(-1) for Se; 29 mu g L(-1) for Sb; 25 mu g L(-1) for Pb; 18 mu g L(-1) for Co.For Group 2 elements:13 mu g L(-1) for Cr; 16 mu g L(-1) for Cu; 53 mu g L(-1) for Fe; 20 mu g L(-1) for Mn.en
dc.description.affiliationFundação Univ Fed Grande Dourados, Fac Ciencias Exatas & Tecnol, BR-79804970 Dourados, MS, Brazil
dc.description.affiliationUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.format.extent147-155
dc.identifier.citationAtomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 30, n. 5, p. 147-155, 2009.
dc.identifier.issn0195-5373
dc.identifier.lattes8708735699846578
dc.identifier.urihttp://hdl.handle.net/11449/25881
dc.identifier.wosWOS:000272362300001
dc.language.isoeng
dc.publisherPerkin-elmer Corp
dc.relation.ispartofAtomic Spectroscopy
dc.relation.ispartofjcr1.123
dc.relation.ispartofsjr0,327
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleSimultaneous Determination of Two Groups of Elements in Milk by Electrothermal Atomic Absorption Spectrometry: Evaluation of Ruthenium Modifiersen
dc.typeArtigo
dcterms.rightsHolderPerkin-elmer Corp
unesp.author.lattes8708735699846578
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Química, Araraquarapt

Arquivos

Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: