Acurácia do teste de escada utilizando o consumo máximo de oxigênio como padrão-ouro

dc.contributor.authorCataneo, Daniele Cristina [UNESP]
dc.contributor.authorCataneo, Antonio José Maria [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:22:25Z
dc.date.available2014-05-27T11:22:25Z
dc.date.issued2007-03-01
dc.description.abstractObjective: To determine the accuracy of the variables related to the fixed-height stair-climbing test (SCT) using maximal oxygen uptake (V̇O 2 max) as the gold standard. Methods: The SCT was performed on a staircase consisting of 6 flights (72 steps; 12.16 m total height), with verbal encouragement, in 51 patients. Stair-climbing time was measured, the variables 'work' and 'power' also being calculated. The V̇O2 max was measured using ergospirometry according to the Balke protocol. We calculated the Pearson linear correlation (r), as well as the values of p, between the SCT variables and V̇O2 max. To determine accuracy, the V̇O 2 max cut-off point was set at 25 mL/kg/min, and individuals were classified as normal or altered. The cut-off points for the SCT variables were determined using the receiver operating characteristic curve. The Kappa statistic (k) was used in order to assess concordance. Results: The following values were obtained for the variable 'time': cut-off point = 40 s; mean = 41 ± 15.5 s; r = -0.707; p < 0.005; specificity = 89%; sensibility = 83%; accuracy = 86%; and k = 0.724. For 'power', the values obtained were as follows: cut-off point = 200 w; mean = 222.3 ± 95.2 w; r = 0.515; p < 0.005; specificity = 67%; sensibility= 75%; accuracy = 71%; and k = 0.414. Since the correlation between the variable 'work' and V̇O2 max was not significant, that variable was discarded. Conclusion: Of the SCT variables tested, using V̇O2 max as the gold standard, the variable 'time' was the most accurate.en
dc.description.affiliationDepartment of Thoracic Surgery Júlio de Mesquita Filho Universidade Estadual Paulista - UNESP, Paulista State University Botucatu School of Medicine, Botucatu (SP)
dc.description.affiliationDepartamento de Cirurgia e Ortopedia UNESP, Distrito de Rubião Jr., s/n, CEP 18618-970, Botucatu, SP
dc.description.affiliationUnespDepartment of Thoracic Surgery Júlio de Mesquita Filho Universidade Estadual Paulista - UNESP, Paulista State University Botucatu School of Medicine, Botucatu (SP)
dc.description.affiliationUnespDepartamento de Cirurgia e Ortopedia UNESP, Distrito de Rubião Jr., s/n, CEP 18618-970, Botucatu, SP
dc.format.extent128-133
dc.identifierhttp://dx.doi.org/10.1590/S1806-37132007000200005
dc.identifier.citationJornal Brasileiro de Pneumologia, v. 33, n. 2, p. 128-133, 2007.
dc.identifier.doi10.1590/S1806-37132007000200005
dc.identifier.file2-s2.0-34848853041.pdf
dc.identifier.issn1806-3713
dc.identifier.scieloS1806-37132007000200005
dc.identifier.scopus2-s2.0-34848853041
dc.identifier.urihttp://hdl.handle.net/11449/69561
dc.language.isopor
dc.language.isoeng
dc.relation.ispartofJornal Brasileiro de Pneumologia
dc.relation.ispartofjcr1.532
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectErgometry
dc.subjectExercise test
dc.subjectHeart function tests
dc.subjectRespiratory function tests
dc.subjectSpirometry
dc.subjectadolescent
dc.subjectadult
dc.subjectaged
dc.subjectepidemiology
dc.subjectergometry
dc.subjectexercise test
dc.subjectfemale
dc.subjecthuman
dc.subjectmale
dc.subjectmethodology
dc.subjectmiddle aged
dc.subjectmotivation
dc.subjectmotor activity
dc.subjectoxygen consumption
dc.subjectphysiology
dc.subjectspirometry
dc.subjectstandard
dc.subjecttime
dc.subjectAdolescent
dc.subjectAdult
dc.subjectAged
dc.subjectEpidemiologic Methods
dc.subjectExercise Test
dc.subjectFemale
dc.subjectHumans
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectMotivation
dc.subjectMotor Activity
dc.subjectOxygen Consumption
dc.subjectTime Factors
dc.titleAcurácia do teste de escada utilizando o consumo máximo de oxigênio como padrão-ouropt
dc.title.alternativeAccuracy of the stair-climbing test using maximal oxygen uptake as the gold standarden
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/jbpneu/paboutj.htm
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatupt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-34848853041.pdf
Tamanho:
244.9 KB
Formato:
Adobe Portable Document Format