Avaliação do pool de plasma caseiro como controle normal para o tempo de tromboplastina parcial ativada (TTP)

dc.contributor.authorHenneberg, Railson [UNESP]
dc.contributor.authorSilva, Paulo Henrique da
dc.contributor.authorKopp, Rogério Luiz
dc.contributor.authorNascimento, Aguinaldo José do
dc.contributor.authorCorrea, Janaína Risczik Arruda
dc.contributor.authorDal Molin, Fernanda
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Uberlândia (UFU)
dc.contributor.institutionUniversidade Federal do Paraná (UFPR)
dc.contributor.institutionSociedade Brasileira de Análises Clínicas
dc.contributor.institutionHospital Universitário Evangélico de Curitiba
dc.date.accessioned2014-05-20T15:08:30Z
dc.date.available2014-05-20T15:08:30Z
dc.date.issued2011-02-01
dc.description.abstractINTRODUÇÃO: A utilização correta de um plasma-controle para a comparação com o plasma do paciente nos testes de coagulação é fundamental para a garantia de um resultado seguro dessas provas laboratoriais. OBJETIVO: O presente estudo analisou a viabilidade do uso de um pool de plasma caseiro, realizado com cinco (P5) e 20 (P20) amostras a partir de pacientes normais, para ser utilizado como controle normal do tempo de tromboplastina parcial (TTP). MATERIAL E MÉTODO: Os dois pools de plasma caseiro foram analisados em relação a um controle normal comercial (AP). Foram 10 dias de experimento e a cada dia os dois pools caseiro eram feitos. Para cada dia foi feito o TTP de P5, P20 e AP. Todos os pacientes com solicitação de TTP, em cada dia do experimento, tiveram a relação de tempos (R) determinada frente a P5, P20 e AP. As ferramentas estatísticas utilizadas foram média (X), análise de variância e teste de Tukey. RESULTADOS: A análise estatística demonstrou que os valores de TTP são significativamente diferentes entre AP e P5 e entre AP e P20, mas não há diferença significativa entre P5 e P20. Quando a relação de tempos foi analisada, não houve diferença significativa entre AP, P5 e P20. CONCLUSÃO: O estudo demonstrou que pode ser utilizado como controle normal um pool de plasma caseiro, feito a partir de cinco ou 20 amostras.pt
dc.description.abstractINTRODUCTION: Proper utilization of plasma control for comparison with the plasma of patients with coagulation tests is critical to ensure a safe outcome of these laboratory tests. OBJECTIVE: The purpose of this work was to know if in-house preparations of polled plasma can be used as a normal control of partial thromboplastin time (PTT). MATERIAL and METHOD: We make two polled plasma, one with five (P5) samples and another with 20 (P20) samples, both of them from normal patients. Both pooled plasma were analyzed in comparison with a commercial lyophilized control (AP). The experiment was performed in 10 days, and P5 and P20 were made daily. At each day PTT was performed for P5, P20 and AP. All patients who asked for TTP, in each day of this experience, got a time relation (R) determined by a P5, P20 e AP. Tukey test was used as statistical analysis. RESULTS: Statistically significant differences were detected among the PTT for AP and P5, AP and P20, but no difference between P5 and P20 was observed. When the time relations were tested, there were no significant difference, among AP, P5, and P20. CONCLUSION: We found that in-house preparations of polled plasma (P5 and P20) can be used as a normal control of PTT.en
dc.description.affiliationUniversidade Estadual Paulista
dc.description.affiliationUniversidade Federal de Uberlândia (UFU)
dc.description.affiliationUFPR
dc.description.affiliationUFPR Departamento de Patologia Médica
dc.description.affiliationUFPR Programa de Pós-graduação em Ciências Farmacêuticas
dc.description.affiliationSociedade Brasileira de Análises Clínicas
dc.description.affiliationHospital Universitário Evangélico de Curitiba
dc.description.affiliationUnespUniversidade Estadual Paulista
dc.format.extent39-42
dc.identifierhttp://dx.doi.org/10.1590/S1676-24442011000100005
dc.identifier.citationJornal Brasileiro de Patologia e Medicina Laboratorial. Sociedade Brasileira de Patologia ClínicaSociedade Brasileira de PatologiaSociedade Brasileira de Citopatologia, v. 47, n. 1, p. 39-42, 2011.
dc.identifier.doi10.1590/S1676-24442011000100005
dc.identifier.fileS1676-24442011000100005.pdf
dc.identifier.issn1676-2444
dc.identifier.scieloS1676-24442011000100005
dc.identifier.urihttp://hdl.handle.net/11449/26891
dc.language.isopor
dc.publisherSociedade Brasileira de Patologia ClínicaSociedade Brasileira de PatologiaSociedade Brasileira de Citopatologia
dc.relation.ispartofJornal Brasileiro de Patologia e Medicina Laboratorial
dc.relation.ispartofsjr0,143
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectTempo de tromboplastina parcial ativadapt
dc.subjectPool de plasma caseiropt
dc.subjectControle de qualidade internopt
dc.subjectPartial thromboplastin timeen
dc.subjectIn-house preparations of pooled plasmaen
dc.subjectQuality controlen
dc.titleAvaliação do pool de plasma caseiro como controle normal para o tempo de tromboplastina parcial ativada (TTP)pt
dc.title.alternativeEvaluation if in-house preparations of polled plasma can be used as a normal control of partial thromboplastin time (PTT)en
dc.typeArtigo

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1676-24442011000100005.pdf
Tamanho:
196 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções