Stpahylococcus aureus biofilms on central venous haemodialysis catheters

dc.contributor.authorAoki, Elisabeth Eyko [UNESP]
dc.contributor.authorPizzolitto, Antonio Carlos [UNESP]
dc.contributor.authorGarcia, Lourdes Botelho
dc.contributor.authorPizzolitto, Elisabeth Loshchagin [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Estadual de Maringá (UEM)
dc.date.accessioned2014-05-20T13:25:18Z
dc.date.available2014-05-20T13:25:18Z
dc.date.issued2005-12-01
dc.description.abstractAs infecções devido a biofilmes bacterianos são comuns em pacientes sob tratamento em hemodiálise. Neste estudo, 16 pacientes (7 homens, 9 mulheres, de 22 a 81 anos, média 50 anos de idade), com um total de 25 cateteres de hemodiálise (3 de triplo-lúmen e 22 de duplo-lúmen) de poliuretano inseridos em veia subclávia foram estudados. Os cateteres permaneceram no local de 3 a 91 dias (média de 47 dias). Os cateteres foram removidos devido ao: mau funcionamento (44%), suspeita de infecção relacionada ao cateter (20%), viabilidade de um acesso permanente (16%), remoção acidental (12%), sinais e sintomas de infecção no local da inserção do cateter (4%) e contaminação exógena (4%). Culturas positivas de ponta foram observadas em sete cateteres (28%), concomitantemente com três culturas positivas de sangue. Das culturas de sangue foram identificados Staphylococcus aureus (12%) e de uma das conexões foi isolado S. aureus. Biofilmes foram observados sobre todas as pontas de cateteres. Os S. aureus isolados do sangue e cateter (ponta e conexão) eram resistentes a pencilina e sensíveis a azitromicina, ciprofloxacina, clindamicina, cloranfenicol, gentamicina, oxacilina, rifampicina, sulfametoxazole, tetraciclina e vancomicina. As cepas de S. aureus isoladas de sangue, ponta de cateter e conexão foram consideradas idênticas devido à coincidência do perfil de sensibilidade. E similaridade genética, avaliada por meio de ribotipagem.pt
dc.description.abstractBiofilm bacterial infections are common in patients undergoing treatment with haemodialysis. This study involved 16 patients (7 males, 9 females; ages from 22 to 81 with an average age of 50) who had had a total of 25 temporary haemodialysis polyurethane catheter insertions into the subclavian vein (22 dual-lumen and 3 triple-lumen). The catheters remained in place from 3 to 91 days, on an average of 47 days. The reasons for catheter removal were: bad functioning (44%), suspicion of catheter-related infection (20%), availability of permanent access (16%), accidental removal (12%), signs and symptoms of infection at the site of catheter insertion (4%), and exogenous contamination (4%). Positive tip cultures were observed on seven of the catheters (28%), showing three positive blood cultures. The Staphylococcus aureus were identified in 12% of the blood cultures and isolated from one of the hubs, and biofilms were observed on all catheter tips. The S. aureus retrieved from both blood and catheters (tips and hubs) were resistant to penicillin and susceptible to azithromycin, ciprofloxacin, clindamycin, chloramphenicol, gentamicin, oxacillin, rifampin, sulfamethoxazole, tetracycline, and vancomycin. The S. aureus strains isolated from both blood and catheters (tips and hubs) were considered to be identical based on antibiotic susceptibility patterns and genetic similarity assessed using an automated ribotyping system.en
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Ciências Farmacêuticas
dc.description.affiliationUniversidade Estadual de Maringá (UEM)
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Ciências Farmacêuticas
dc.format.extent342-346
dc.identifierhttp://dx.doi.org/10.1590/S1517-83822005000400007
dc.identifier.citationBrazilian Journal of Microbiology. Sociedade Brasileira de Microbiologia, v. 36, n. 4, p. 342-346, 2005.
dc.identifier.doi10.1590/S1517-83822005000400007
dc.identifier.fileS1517-83822005000400007.pdf
dc.identifier.issn1517-8382
dc.identifier.scieloS1517-83822005000400007
dc.identifier.urihttp://hdl.handle.net/11449/8007
dc.language.isoeng
dc.publisherSociedade Brasileira de Microbiologia
dc.relation.ispartofBrazilian Journal of Microbiology
dc.relation.ispartofjcr1.810
dc.relation.ispartofsjr0,630
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectbiofilmept
dc.subjectcateter em hemodiálisept
dc.subjectcateter venoso centralpt
dc.subjectinfecções relacionadas ao cateterpt
dc.subjectbiofilmen
dc.subjectcatheter in haemodialysisen
dc.subjectcentral venous catheteren
dc.subjectcatheter-related infectionsen
dc.titleStpahylococcus aureus biofilms on central venous haemodialysis cathetersen
dc.title.alternativeBiofilmes de Staphylococcus aureus em cateter venoso central em hemodiálisept
dc.typeArtigo
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Ciências Farmacêuticas, Araraquarapt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1517-83822005000400007.pdf
Tamanho:
192.12 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: