Adaptação da máscara do analisador de gases VO2000 para mensuração de parâmetros cardiorrespiratórios em natação

dc.contributor.authorPapoti, Marcelo [UNESP]
dc.contributor.authorBalikian Junior, Pedro [UNESP]
dc.contributor.authorDenadai, Benedito Sergio [UNESP]
dc.contributor.authorLima, Manoel Carlos Spiguel [UNESP]
dc.contributor.authorSilva, Adelino Sanchez da [UNESP]
dc.contributor.authorSanthiago, Vanessa [UNESP]
dc.contributor.authorGobatto, Claudio Alexandre [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionFIB Centro de Estudos e Pesquisa da Atividade Física
dc.contributor.institutionUniversidade do Oeste Paulista (UNOESTE)
dc.date.accessioned2013-09-30T19:28:23Z
dc.date.accessioned2014-05-20T13:58:14Z
dc.date.available2013-09-30T19:28:23Z
dc.date.available2014-05-20T13:58:14Z
dc.date.issued2007-06-01
dc.description.abstractO objetivo do presente estudo foi desenvolver um snorquel (SNQ) de baixo custo para mensuração de parâmetros cardiorrespiratórios em natação. Para isso, a máscara do analisador de gases VO2000 (MASC) foi adaptada a um SNQ desenvolvido artesanalmente com espaço morto de 250ml. Oito participantes foram submetidos a dois testes incrementais (TI) em cicloergômetro utilizando a MASC e o SNQ. Os TI foram realizados até a exaustão voluntária e foram compostos por estágios de 3min com carga inicial e incrementos de 35W. em ambas as situações, amostras gasosas foram coletadas em intervalos de 10s para determinação dos volumes de oxigênio (VO2), gás carbônico (VCO2), ventilatório (VE) e mensuração da freqüência cardíaca (FC). A comparação dos parâmetros cardiorrespiratórios (VO2, VE, VCO2 e FC) mensurados com o SNQ e a MASC foi realizada com o teste t de Student para amostras dependentes, enquanto que o teste de correlação de Pearson e a análise gráfica de Bland e Altman foram utilizados para verificar as associações e concordância entre parâmetros. em todos os casos, o nível de significância foi de P < 0,05. A adequação das equações de correção para os valores provenientes do SNQ foi verificada pelos erros sistemáticos (bias), aleatórios (precisão) e acurácia (ac). Não foram observadas diferenças significativas entre os valores de VO2, VCO2 e FC obtidos com a MASC e SNQ. Os valores de VE mensurados com o SNQ foram significativamente superiores aos obtidos com a MASC. No entanto, todos os parâmetros apresentaram elevada concordância e coeficiente de correlação (0,88 a 0,97). Além disso, foram verificados reduzidos valores de bias (VO2 = 0,11L/min; VE = 4,11L/min; VCO2 = 0,54L/min; 8,87bpm), precisão (VO2 = 0,24L/min; VE = 11,02L/ min; VCO2 = 0,18L/min; 7,42bpm) e ac (VO2 = 0,27L/min; VE = 11,76L/min; VCO2 = 0,56L/min; 11,56bpm). Desse modo, pode-se concluir que o SNQ desenvolvido neste estudo possibilita a mensuração válida de parâmetros cardiorrespiratórios em natação.pt
dc.description.abstractThe aim of the present study was to develop a snorkel (SNK) with low cost for cardio respiratory parameters measurement in swimming. So, a mask of gas analyzer VO2000 (MASK) was adapted to a SNQ developed by man craftwork form with dead space of 250 ml. Eight subjects were submitted to two incremental tests (IT) on cycloergometer using the MASK and the SNK. The IT(s) occurred until voluntary exhaustion and it was composed per stages of 3 min and with initial load and grade increment of 35 W. In both situations, gaseous samples were collected in intervals of 10 s for determination of the amount of oxygen (VO2), of carbonic gas (VCO2) and of ventilatory volume (VE); heart rate (HR) measurement was done with monitor frequency heart (Polar). The comparison of the cardiorespiratory parameters (VO2, VE, VCO2) and HR measured with a SNK and a MASK was performed with the Student's t test of dependent samples, while the Pearson's correlation test and graphic analyzer of Bland and Altman were performed to verify the associations and agreement among parameters. In all cases the level of significance was P < 0.05. The appropriate equations of the correction of values originating from SNK was verified by systematic error (bias), aleatory (precision) and accuracy (ac). It was not found significant differences among the values of VO2, VCO2 and HR obtained with the MASK and SNK. The values of VE measured with SNK were found significantly higher than the obtained with the MASK. However, all parameters presented high agreement and correlation (0.88 to 0.97). Besides, low values of bias (VO2 = 0.11 L/min; VE = 4.11 L/min; VCO2 = 0.54 L/min; 8.87 bpm), precision (VO2 = 0,24 L/min; VE = 11.02 L/min; VCO2 = 0,18 L/min; 7.42 bpm) and accuracy (VO2 = 0,27 L/min; VE = 11.76 L/min; VCO2 = 0.56 L/min; 11.56 bpm) were verified. Thereby, we could conclude that the SNK developed in this study allow a validate measurement of cardiorespiratory parameters in swimming.en
dc.description.affiliationUNESP Laboratório de Fisiologia Aplicada ao Esporte
dc.description.affiliationFIB Centro de Estudos e Pesquisa da Atividade Física
dc.description.affiliationUniversidade do Oeste Paulista (UNOESTE)
dc.description.affiliationUnespUNESP Laboratório de Fisiologia Aplicada ao Esporte
dc.format.extent190-194
dc.identifierhttp://dx.doi.org/10.1590/S1517-86922007000300012
dc.identifier.citationRevista Brasileira de Medicina do Esporte. Sociedade Brasileira de Medicina do Exercício e do Esporte, v. 13, n. 3, p. 190-194, 2007.
dc.identifier.doi10.1590/S1517-86922007000300012
dc.identifier.fileS1517-86922007000300012.pdf
dc.identifier.issn1517-8692
dc.identifier.lattes1907479250833033
dc.identifier.scieloS1517-86922007000300012
dc.identifier.urihttp://hdl.handle.net/11449/20700
dc.language.isopor
dc.publisherSociedade Brasileira de Medicina do Exercício e do Esporte
dc.relation.ispartofRevista Brasileira de Medicina do Esporte
dc.relation.ispartofjcr0.270
dc.relation.ispartofsjr0,185
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectNataçãopt
dc.subjectSnorquelpt
dc.subjectConsumo de oxigêniopt
dc.subjectVolume ventilatóriopt
dc.subjectFreqüência cardíacapt
dc.subjectSwimmingen
dc.subjectSnorkelen
dc.subjectOxygen uptakeen
dc.subjectVentilatory volumeen
dc.subjectHeart rateen
dc.titleAdaptação da máscara do analisador de gases VO2000 para mensuração de parâmetros cardiorrespiratórios em nataçãopt
dc.title.alternativeAdaptation of the VO2000 gas analiser's mask to mensuration of cardiorespiratory parameters in swimmingen
dc.typeArtigo
unesp.author.lattes1907479250833033[3]
unesp.author.orcid0000-0003-0775-1889[3]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Biociências, Rio Claropt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1517-86922007000300012.pdf
Tamanho:
558.86 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: