Comparison between two methods for cardiac output measurement in propofol-anesthetized dogs: thermodilution and Doppler

dc.contributor.authorFerro Lopes, Patricia Cristina [UNESP]
dc.contributor.authorSousa, Marlos Goncalves
dc.contributor.authorCamacho, Aparecido Antonio [UNESP]
dc.contributor.authorCarareto, Roberta
dc.contributor.authorNishimori, Celina T. D.
dc.contributor.authorSantos, Paulo S. P. [UNESP]
dc.contributor.authorNunes, Newton [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal do Tocantins (UFT)
dc.contributor.institutionUniv Franca
dc.date.accessioned2014-05-20T13:14:16Z
dc.date.available2014-05-20T13:14:16Z
dc.date.issued2010-09-01
dc.description.abstractObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.en
dc.description.affiliationUniv Estadual Paulista, Dept Vet Med & Surg, Vet Surg Postgrad Program, Coll Agr & Vet Sci, BR-14884900 São Paulo, Brazil
dc.description.affiliationUniversidade Federal do Tocantins (UFT), Sch Vet Med & Zootecnia, Araguaina, Tocantins, Brazil
dc.description.affiliationUniv Franca, Anesthesiol & Vet Surg Postgrad Program, São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Dept Clin Surg & Anim Reprod, Coll Agr & Vet Sci, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Vet Med & Surg, Vet Surg Postgrad Program, Coll Agr & Vet Sci, BR-14884900 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Clin Surg & Anim Reprod, Coll Agr & Vet Sci, São Paulo, Brazil
dc.format.extent401-408
dc.identifierhttp://dx.doi.org/10.1111/j.1467-2995.2010.00552.x
dc.identifier.citationVeterinary Anaesthesia and Analgesia. Malden: Wiley-blackwell, v. 37, n. 5, p. 401-408, 2010.
dc.identifier.doi10.1111/j.1467-2995.2010.00552.x
dc.identifier.issn1467-2987
dc.identifier.lattes9642688764978907
dc.identifier.lattes0023783814889740
dc.identifier.orcid0000-0002-8535-5569
dc.identifier.urihttp://hdl.handle.net/11449/1788
dc.identifier.wosWOS:000281002400002
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofVeterinary Anaesthesia and Analgesia
dc.relation.ispartofjcr2.064
dc.relation.ispartofsjr0,800
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectAnesthesiaen
dc.subjectcardiac outputen
dc.subjectDogen
dc.subjectechocardiographyen
dc.titleComparison between two methods for cardiac output measurement in propofol-anesthetized dogs: thermodilution and Doppleren
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
unesp.author.lattes9642688764978907[3]
unesp.author.lattes0023783814889740
unesp.author.orcid0000-0002-8535-5569[6]
unesp.author.orcid0000-0001-9802-9271[3]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Ciências Agrárias e Veterinárias, Jaboticabalpt

Arquivos

Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: