Electromyographic preactivation pattern of the gluteus medius during weight-bearing functional tasks in women with and without anterior knee pain

dc.contributor.authorNakagawa, Theresa H.
dc.contributor.authorMuniz, Thiago B.
dc.contributor.authorBaldon, Rodrigo M.
dc.contributor.authorMaciel, Carlos D.
dc.contributor.authorAmorim, César F. [UNESP]
dc.contributor.authorSerrão, Fábio V.
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:28:28Z
dc.date.available2014-05-20T13:28:28Z
dc.date.issued2011-02-01
dc.description.abstractCONTEXTUALIZAÇÃO: Tem sido proposto que fatores proximais influenciam a biomecânica da articulação fêmoro-patelar. Um atraso ou diminuição da ativação do glúteo médio (GM) antes do contato do pé no solo, durante atividades funcionais, poderia levar a adução e rotação interna excessiva do fêmur e provocar a dor anterior do joelho (DAJ). Existem poucos estudos sobre o assunto, e os resultados não foram conclusivos; assim, há necessidade de estudar a pré-ativação do GM durante atividades funcionais. OBJETIVO: Comparar o padrão de pré-ativação eletromiográfica (EMG) do GM durante a caminhada, descida de degraus e salto unipodal entre mulheres com e sem DAJ. MÉTODOS: Nove mulheres com diagnóstico clínico de DAJ e dez mulheres sem história de lesão no joelho participaram do estudo. Avaliou-se a envoltória linear do sinal EMG do GM antes do contato do pé no solo, durante caminhada; o tempo de ativação do GM e a envoltória linear do sinal EMG durante descida de degraus e salto unipodal. Utilizou-se o teste Mann-Whitney para determinar a diferença intergrupos no padrão de pré-ativação EMG do GM. RESULTADOS: Não se encontrou nenhuma diferença intergrupos na envoltória linear do GM durante caminhada (P=0.41), no tempo de ativação e na envoltória linear, durante descida de degraus (P=0.17 e P=0.15) e salto unipodal (P=0.81 e P=0.33). CONCLUSÕES: Mulheres com DAJ não apresentaram alterações significativas no padrão de pré-ativação do GM durante atividades funcionais. Os presentes resultados não sustentam a hipótese de que o pobre padrão de pré-ativação do GM esteja envolvido na DAJ.pt
dc.description.abstractBACKGROUND: Proximal factors have been proposed to influence the biomechanics of the patellofemoral joint. A delayed or diminished gluteus medius (GM) activation, before the foot contact on the ground during functional activities could lead to excessive femur adduction and internal rotation and be associated with anterior knee pain (AKP). There are few studies on this topic and the results were inconclusive, therefore, it is necessary to investigate the GM preactivation pattern during functional activities. OBJECTIVE: To compare the GM electromyographic (EMG) preactivation pattern during walking, descending stairs and in single leg jump task in women with and without AKP. METHODS: Nine women clinically diagnosed with AKP and ten control subjects with no history of knee injury participated in this study. We evaluated GM EMG linear envelope before the foot contact on the ground during walking and GM onset time and EMG linear envelope during descending stairs as well as in a single leg vertical jump. Mann-Whitney U tests were used to determine the between-group differences in GM EMG preactivation pattern. RESULTS: No between-group differences were observed in GM linear envelope during walking (P=0.41), GM onset time and linear envelope during descending stairs (P=0.17 and P=0.15) and single leg jump (P=0.81 and P=0.33). CONCLUSIONS: Women with AKP did not demonstrated altered GM preactivation pattern during functional weight bearing activities. Our results did not support the hypothesis that poor GM preactivation pattern could be associated with AKP.en
dc.description.affiliationUniversidade Federal de São Carlos (UFSCar) Physical Therapy Department
dc.description.affiliationUniversidade de São Paulo Electrical Engineering Department
dc.description.affiliationUniversidade Estadual Paulista Mechanical Engineering Department
dc.description.affiliationUnespUniversidade Estadual Paulista Mechanical Engineering Department
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.format.extent59-65
dc.identifierhttp://dx.doi.org/10.1590/S1413-35552011005000003
dc.identifier.citationBrazilian Journal of Physical Therapy. Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia , v. 15, n. 1, p. 59-65, 2011.
dc.identifier.doi10.1590/S1413-35552011005000003
dc.identifier.fileS1413-35552011000100010.pdf
dc.identifier.issn1413-3555
dc.identifier.scieloS1413-35552011000100010
dc.identifier.urihttp://hdl.handle.net/11449/9474
dc.identifier.wosWOS:000289857600010
dc.language.isoeng
dc.publisherAssociação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
dc.relation.ispartofBrazilian Journal of Physical Therapy
dc.relation.ispartofjcr1.699
dc.relation.ispartofsjr0,802
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectdor anterior do joelhopt
dc.subjectmusculatura do quadrilpt
dc.subjectEMG de superfíciept
dc.subjectanterior knee painen
dc.subjecthip muscleen
dc.subjectsurface EMGen
dc.titleElectromyographic preactivation pattern of the gluteus medius during weight-bearing functional tasks in women with and without anterior knee painen
dc.title.alternativePadrão de pré-ativação eletromiográfica do glúteo médio durante atividades funcionais com descarga de peso em mulheres com e sem dor anterior do joelhopt
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/rbfis/paboutj.htm
unesp.author.orcid0000-0003-0137-6678[4]

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1413-35552011000100010.pdf
Tamanho:
284.29 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções