Análise térmica do processo de incineração de resíduos aquosos com chamas enriquecidas

dc.contributor.authorLacava, Pedro Teixeira
dc.contributor.authorDe Carvalho Jr., João Andrade [UNESP]
dc.contributor.authorPimenta, Amilcar Porto
dc.contributor.authorFerreira, Marco Aurélio
dc.contributor.institutionInst. Tecnol. de Aeronáutica
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionInstituto Nacional de Pesquisas Espaciais (INPE)
dc.date.accessioned2014-05-27T11:21:00Z
dc.date.available2014-05-27T11:21:00Z
dc.date.issued2003-12-01
dc.description.abstractThe use of oxygen to enrich the combustion air can be an attractive technique to increase capacity of an incinerator originally designed to operate with air. If incinerator parameters such as operation temperature, turbulence level and residence time are fixed for a certain fuel supply rate, it is possible to increase the residue consumption rate using enriched air. This paper presents the thermal analysis for operation with enriched air of an aqueous residue experimental incinerator. The auxiliary fuel was diesel oil. The theoretical results showed that there is a considerable increase in the incineration ratio up to approximately 50 % of O 2 in the oxidiser. The tendency was confirmed experimentally. Thermal analysis was demonstrated to be an important tool to predict possible incinerator capacity increase.en
dc.description.affiliationInst. Tecnol. de Aeronáutica, São José dos Campos
dc.description.affiliationUniversidade Estadual Paulista, Guarantingueta
dc.description.affiliationInst. Nac. de Pesquisas Espaciais, Cachoeira Paulista
dc.description.affiliationUnespUniversidade Estadual Paulista, Guarantingueta
dc.format.extent164-173
dc.identifier.citation58th Congresso Anual da ABM (ASSociacao Brasileira de Metalurgia e Materiais), p. 164-173.
dc.identifier.lattes1663295770796752
dc.identifier.scopus2-s2.0-1842421378
dc.identifier.urihttp://hdl.handle.net/11449/67573
dc.language.isopor
dc.relation.ispartof58th Congresso Anual da ABM (ASSociacao Brasileira de Metalurgia e Materiais)
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectEnriched combustion
dc.subjectIncineration
dc.subjectThermal analysis
dc.subjectIncinerator capacity
dc.subjectDiesel fuels
dc.subjectRefuse incinerators
dc.subjectThermoanalysis
dc.subjectTurbulence
dc.subjectFlame research
dc.titleAnálise térmica do processo de incineração de resíduos aquosos com chamas enriquecidaspt
dc.title.alternativeThermal analysis of enriched flame incinerators for aqueous residuesen
dc.typeTrabalho apresentado em evento
unesp.advisor.lattes1663295770796752