Determinação de carbaril utilizando testes ELISA (Enzyme-linked immunosorbent assay) e CLAE com detecção por arranjo de diodos

dc.contributor.authorToscano, Ilda A. S. [UNESP]
dc.contributor.authorRibeiro, M. Lúcia [UNESP]
dc.contributor.authorRocha, Julio C. [UNESP]
dc.contributor.authorNunes, Gilvanda S.
dc.contributor.authorBarceló, Damiá
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal do Maranhão (UFMA)
dc.contributor.institutionCentro de Investigación y Desarrollo Departamento Química Ambiental
dc.date.accessioned2014-05-20T15:10:17Z
dc.date.available2014-05-20T15:10:17Z
dc.date.issued2000-08-01
dc.description.abstractELISAs have been applied to pesticide residue analysis due to their high sensitivity and selectivity. However, some ELISAs performance may be affected by matrix components. In this work, ELISA for carbaryl in water samples was checked for interference by naturally occurring fulvic acids. The results suggested that the high fulvic acid concentration ( ³30 mg L-1) and acidic pH conditions (pH 4.0) interfere with the signal detection decreasing the method sensitivity. A dilution of the samples and adjust to pH 8.0 are appropriate to minimize the matrix interferences in the ELISA method. Good correlation between ELISA and HPLC-DAD results was observed.en
dc.description.affiliationUniversidade Estadual Paulista Instituto de Química
dc.description.affiliationUniversidade Federal do Maranhão Departamento Química Tecnológica
dc.description.affiliationCentro de Investigación y Desarrollo Departamento Química Ambiental
dc.description.affiliationUnespUniversidade Estadual Paulista Instituto de Química
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.format.extent466-471
dc.identifierhttp://dx.doi.org/10.1590/S0100-40422000000400007
dc.identifier.citationQuímica Nova. Sociedade Brasileira de Química, v. 23, n. 4, p. 466-471, 2000.
dc.identifier.doi10.1590/S0100-40422000000400007
dc.identifier.fileS0100-40422000000400007.pdf
dc.identifier.issn0100-4042
dc.identifier.scieloS0100-40422000000400007
dc.identifier.urihttp://hdl.handle.net/11449/27569
dc.language.isopor
dc.publisherSociedade Brasileira de Química
dc.relation.ispartofQuímica Nova
dc.relation.ispartofjcr0.646
dc.relation.ispartofsjr0,255
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectELISAen
dc.subjectcarbarylen
dc.subjectfulvic acidsen
dc.titleDeterminação de carbaril utilizando testes ELISA (Enzyme-linked immunosorbent assay) e CLAE com detecção por arranjo de diodospt
dc.title.alternativeDetermination of carbaryl by ELISA (Enzyme-linked immunosorbent assay) and HPLC with photodiode array detectionen
dc.typeArtigo

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0100-40422000000400007.pdf
Tamanho:
58.92 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções