Publicação: Hardening of a dual-cure resin cement using QTH and LED curing units
dc.contributor.author | Moraes Coelho Santos, Maria Jacinta | |
dc.contributor.author | Passos, Sheila Pestana [UNESP] | |
dc.contributor.author | Lessa da Encarnacao, Monalisa Olga | |
dc.contributor.author | Santos Junior, Gildo Coelho | |
dc.contributor.author | Bottino, Marco Antonio [UNESP] | |
dc.contributor.institution | Univ Western Ontario | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal da Bahia (UFBA) | |
dc.date.accessioned | 2014-05-20T14:05:07Z | |
dc.date.available | 2014-05-20T14:05:07Z | |
dc.date.issued | 2010-03-01 | |
dc.description.abstract | Objective: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light- emitting diode (LED) or quartz tungsten halogen (QTH) light source. Material and Methods: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. Results: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. Conclusions: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values. | en |
dc.description.affiliation | Univ Western Ontario, Dept Restorat Dent, London, on N6A 3K7, Canada | |
dc.description.affiliation | São Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, Brazil | |
dc.description.affiliation | Universidade Federal da Bahia (UFBA), Sch Dent, Dept Dent Mat & Prosthodont, Salvador, BA, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, Brazil | |
dc.format.extent | 110-115 | |
dc.identifier | http://dx.doi.org/10.1590/S1678-77572010000200003 | |
dc.identifier.citation | Journal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 18, n. 2, p. 110-115, 2010. | |
dc.identifier.file | S1678-77572010000200003.pdf | |
dc.identifier.issn | 1678-7757 | |
dc.identifier.lattes | 9234456003563666 | |
dc.identifier.scielo | S1678-77572010000200003 | |
dc.identifier.uri | http://hdl.handle.net/11449/22838 | |
dc.identifier.wos | WOS:000277832000003 | |
dc.language.iso | eng | |
dc.publisher | Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru | |
dc.relation.ispartof | Journal of Applied Oral Science | |
dc.relation.ispartofjcr | 1.709 | |
dc.relation.ispartofsjr | 0,645 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | Hardness | en |
dc.subject | Cure | en |
dc.subject | Resin cements | en |
dc.title | Hardening of a dual-cure resin cement using QTH and LED curing units | en |
dc.type | Artigo | |
dcterms.license | http://www.scielo.br/revistas/jaos/paboutj.htm | |
dcterms.rightsHolder | Univ São Paulo Fac Odontologia Bauru | |
dspace.entity.type | Publication | |
unesp.author.lattes | 9234456003563666 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- S1678-77572010000200003.pdf
- Tamanho:
- 59.57 KB
- Formato:
- Adobe Portable Document Format
- Descrição:
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: