Publicação: Effect of disinfection treatments on the hardness of soft denture liner materials
dc.contributor.author | Pavan, Sabrina [UNESP] | |
dc.contributor.author | Arioli Filho, João Neudenir [UNESP] | |
dc.contributor.author | Santos, Paulo Henrique dos [UNESP] | |
dc.contributor.author | Nogueira, Sergio Sualdini [UNESP] | |
dc.contributor.author | Batista, André Ulisses Dantas | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Federal University of Paraíba | |
dc.date.accessioned | 2014-05-27T11:22:25Z | |
dc.date.available | 2014-05-27T11:22:25Z | |
dc.date.issued | 2007-03-01 | |
dc.description.abstract | Purpose: To evaluate the effects of disinfection treatments with chemical solutions (2% glutaraldehyde, 5% sodium hypochlorite, and 5% chlorhexidine) and microwave energy on the hardness of four long-term soft denture liners. Materials and Methods: Forty rectangular specimens of four soft lining materials (Molloplast-B, Ufi Gel P, Eversoft, and Mucopren soft) were made for each material. Ten samples of each material were immersed in different disinfectant solutions for 10 minutes or placed in a microwave oven for 3 minutes at 500 W. The hardness values were obtained with a Shore A durometer, before the first disinfection cycle (control), and also after two cycles of disinfection. Data were submitted to analysis of variance and Tukey's test (p < 0.01). Results: The highest value of hardness was obtained for Molloplast-B, independent of the disinfection technique. Mucopren soft demonstrated intermediate values and Ufi Gel P and Eversoft the lowest values of Shore A hardness. For Molloplast-B, the disinfection using glutaraldehyde demonstrated the highest value of hardness. The number of disinfections had no effect on the hardness values for all the materials studied and disinfection techniques. Conclusions: The application of two disinfection cycles did not change the Shore A hardness values for all the materials. The glutaraldehyde solution demonstrated the highest values of Shore A hardness for the Molloplast-B, Mucopren soft, and Ufi Gel P materials, while Eversoft did not present any differences in hardness when submitted to different disinfection treatments. Copyright © 2007 by The American College of Prosthodontists. | en |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo | |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University, Araçatuba, São Paulo | |
dc.description.affiliation | Department of Restorative Dentistry Federal University of Paraíba, João Pessoa, Paraíba | |
dc.description.affiliation | , R. Presidente Bernardes, 482 ap. 144, Araçatuba, SP 6015-353 | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University, Araçatuba, São Paulo | |
dc.format.extent | 101-106 | |
dc.identifier | http://dx.doi.org/10.1111/j.1532-849X.2007.00162.x | |
dc.identifier.citation | Journal of Prosthodontics, v. 16, n. 2, p. 101-106, 2007. | |
dc.identifier.doi | 10.1111/j.1532-849X.2007.00162.x | |
dc.identifier.issn | 1059-941X | |
dc.identifier.issn | 1532-849X | |
dc.identifier.lattes | 0493479801083622 | |
dc.identifier.orcid | 0000-0002-4100-5153 | |
dc.identifier.scopus | 2-s2.0-33947238827 | |
dc.identifier.uri | http://hdl.handle.net/11449/69541 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Prosthodontics | |
dc.relation.ispartofjcr | 1.745 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Scopus | |
dc.subject | Disinfection | |
dc.subject | Hardness | |
dc.subject | Soft liner material | |
dc.subject | denture | |
dc.subject | disinfection | |
dc.subject | drug effect | |
dc.subject | hardness | |
dc.subject | microwave radiation | |
dc.subject | radiation exposure | |
dc.subject | Denture Liners | |
dc.subject | Microwaves | |
dc.title | Effect of disinfection treatments on the hardness of soft denture liner materials | en |
dc.type | Artigo | pt |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 6380225075834021 | |
unesp.author.lattes | 0872749896035329 | |
unesp.author.lattes | 0493479801083622[3] | |
unesp.author.orcid | 0000-0002-4100-5153[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |