Publicação:
Integrated analysis of halogenated organic pollutants in sub-millilitre volumes of venous and umbilical cord blood sera

dc.contributor.authorGrimalt, Joan O.
dc.contributor.authorHowsam, Mike
dc.contributor.authorCarrizo, Daniel
dc.contributor.authorOtero, Raquel
dc.contributor.authorMarchi, Mary Rosa Rodrigues de [UNESP]
dc.contributor.authorVizcaino, Esther
dc.contributor.institutionInstitute of Environmental Assessment and Water Research (IDÆA-CSIC)
dc.contributor.institutionUniversité de Lille 2
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:24:38Z
dc.date.available2014-05-27T11:24:38Z
dc.date.issued2010-03-01
dc.description.abstractA rapid, robust and economical method for the analysis of persistent halogenated organic compounds in small volumes of human serum and umbilical cord blood is described. The pollutants studied cover a broad range of molecules of contemporary epidemiological and legislative concern, including polychlorobiphenyls (PCBs), polychlorobenzenes (CBs), hexachlorocyclohexanes (HCHs), DDTs, polychlorostyrenes (PCSs) and polybromodiphenyl ethers (PBDEs). Extraction and clean-up with n-hexane and concentrated sulphuric acid was followed with analysis by gas chromatography coupled to electron capture (GC-ECD) and GC coupled to negative ion chemical ionisation mass spectrometry (GC-NICI-MS). The advantages of this method rest in the broad range of analytes and its simplicity and robustness, while the use of concentrated sulphuric acid extraction/clean-up destroys viruses that may be present in the samples. Small volumes of reference serum between 50 and 1000 μL were extracted and the limits of detection/quantification and repeatability were determined. Recoveries of spiked compounds for the extraction of small volumes (≥300 μL) of the spiked reference serum were between 90% and 120%. The coefficients of variation of repeatability ranged from 0.1-14%, depending on the compound. Samples of 4-year-old serum and umbilical cord blood (n = 73 and 40, respectively) from a population inhabiting a village near a chloro-alkali plant were screened for the above-mentioned halogenated pollutants using this method and the results are briefly described. © 2010 Springer-Verlag.en
dc.description.affiliationDepartment of Environmental Chemistry Institute of Environmental Assessment and Water Research (IDÆA-CSIC), Jordi Girona, 18, Barcelona, Catalonia 08034
dc.description.affiliationCentre Universitaire de Mesure et d'Analyse Faculté de Pharmacie Université de Lille 2, 3 rue de Professeur Laguesse, Lille Cedex 59006
dc.description.affiliationDepartment of Analytical Chemistry Institute of Chemistry UNESP, Araraquara, SP 14801-970
dc.description.affiliationUnespDepartment of Analytical Chemistry Institute of Chemistry UNESP, Araraquara, SP 14801-970
dc.format.extent2265-2272
dc.identifierhttp://dx.doi.org/10.1007/s00216-010-3460-y
dc.identifier.citationAnalytical and Bioanalytical Chemistry, v. 396, n. 6, p. 2265-2272, 2010.
dc.identifier.doi10.1007/s00216-010-3460-y
dc.identifier.issn1618-2642
dc.identifier.issn1618-2650
dc.identifier.lattes2543372149131902
dc.identifier.scopus2-s2.0-77951295081
dc.identifier.urihttp://hdl.handle.net/11449/71583
dc.language.isoeng
dc.relation.ispartofAnalytical and Bioanalytical Chemistry
dc.relation.ispartofjcr3.307
dc.relation.ispartofsjr0,978
dc.relation.ispartofsjr0,978
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectBlood serum
dc.subjectEndocrine disruptors
dc.subjectGC-ECD
dc.subjectGC-MS
dc.subjectPesticides
dc.subjectTrace halogenated organic compounds
dc.subjectUmbilical cord serum
dc.subjectVenous serum
dc.subjectEndocrine disruptor
dc.subjectHalogenated organic compounds
dc.subjectUmbilical cords
dc.subjectAlkalinity
dc.subjectBlood
dc.subjectElectrochemical sensors
dc.subjectElectrochromic devices
dc.subjectEthers
dc.subjectGas chromatography
dc.subjectHalogenation
dc.subjectHexane
dc.subjectMass spectrometry
dc.subjectPolychlorinated biphenyls
dc.subjectReduction
dc.subjectSulfuric acid
dc.subjectViruses
dc.subjectOrganic pollutants
dc.subjecthalogenated hydrocarbon
dc.subjectblood
dc.subjectchemistry
dc.subjectelectrospray mass spectrometry
dc.subjectevaluation
dc.subjectfemale
dc.subjectfetus blood
dc.subjectgas chromatography
dc.subjecthuman
dc.subjectmale
dc.subjectmethodology
dc.subjectpollutant
dc.subjectpreschool child
dc.subjectserum
dc.subjectstatistical parameters
dc.subjectChild, Preschool
dc.subjectChromatography, Gas
dc.subjectEnvironmental Pollutants
dc.subjectFemale
dc.subjectFetal Blood
dc.subjectHumans
dc.subjectHydrocarbons, Halogenated
dc.subjectLimit of Detection
dc.subjectMale
dc.subjectSerum
dc.subjectSpectrometry, Mass, Electrospray Ionization
dc.titleIntegrated analysis of halogenated organic pollutants in sub-millilitre volumes of venous and umbilical cord blood seraen
dc.typeArtigo
dcterms.licensehttp://www.springer.com/open+access/authors+rights
dspace.entity.typePublication
unesp.author.lattes2543372149131902
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos