dc.description.abstractPurpose: The aim of this systematic review was to compare straight-line and offset implant configurations for three-element implant-retained prostheses. Materials and Methods: Two independent reviewers conducted a review on PubMed/Medline, EMBASE, and Cochrane Library for studies published in English, from January 1, 1995 to January 17, 2014. A systematic review was conducted following the PRISMA statement. All relevant titles were selected according to inclusion/exclusion criteria. From this pool of titles, abstracts and full texts were reviewed. Results: A total of 6080 titles were identified with the initial search. Twenty-one were selected based on title and abstract. Of these, after discussion and complete reading, 12 studies were selected according to the inclusion and exclusion criteria, all of which were in vitro studies. Conclusions: A systematic review of the current literature showed only in vitro evidence that there is no consensus on the advantage of using an offset configuration implant compared to those in straight-line configuration, even though some studies present a slight improvement of bone stress distribution when an offset implant is under oblique loading (PICO).en
dc.description.affiliationUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia de Araçatuba (FOA), Departamento de Materiais Odontológicos e Prótese, BR-16015050 Araçatuba, SP, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia de Araçatuba (FOA), Departamento de Materiais Odontológicos e Prótese, BR-16015050 Araçatuba, SP, Brasil
dc.format.extent93-99
dc.identifierhttp://onlinelibrary.wiley.com/doi/10.1111/jopr.12221/abstract
dc.identifier.citationJournal Of Prosthodontics-implant Esthetic And Reconstructive Dentistry. Hoboken: Wiley-blackwell, v. 24, n. 2, p. 93-99, 2015.
dc.identifier.doi10.1111/jopr.12221
dc.identifier.issn1059-941X
dc.identifier.lattes5581364193525500
dc.identifier.urihttp://hdl.handle.net/11449/128494
dc.identifier.wosWOS:000350152100001
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofJournal Of Prosthodontics-implant Esthetic And Reconstructive Dentistry
dc.relation.ispartofjcr1.745
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectDental implantsen
dc.subjectImplant-retained dental prosthesisen
dc.subjectProsthodonticsen
dc.subjectBiomechanicsen
dc.titleThe effect of offset implant configuration on bone stress distribution: a systematic reviewen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-Blackwell
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes5581364193525500
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos