Logotipo do repositório
 

Publicação:
Impact of process and device dimensions on Bio-TFET Sensitivity

Carregando...
Imagem de Miniatura

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Ieee

Tipo

Trabalho apresentado em evento

Direito de acesso

Acesso abertoAcesso Aberto

Resumo

This paper reports the impact of process and dimensions on the sensitivity of the double gate Bio-TFET for drain and source underlap structures. The Bio-TFET is simulated using different dielectric permittivity materials (epsilon) localized over the drain to gate and gate to source underlap regions. The impact of silicon thickness (t(Si)), gate oxide (t(ox)), underlap length at the source (L-US) and at the drain region (L-UD) were studied. The best sensitivity for Bio-TFET biosensor is obtained for the source underlap (L-US) of 25 nm, channel silicon thickness of 5 nm and gate oxide thickness of 3 nm. The energy band diagram and the band-to-band tunneling generation rate were used to explain the results.

Descrição

Palavras-chave

TFET, Biosensor, Bio-TFET, Tunnel-FET

Idioma

Inglês

Como citar

2018 Ieee Soi-3d-subthreshold Microelectronics Technology Unified Conference (s3s). New York: Ieee, 3 p., 2018.