Logotipo do repositório
 

Publicação:
Avaliação Clínica de Duas ke0 no Mesmo Modelo Farmacocinético de Propofol: Estudo da Perda e Recuperação da Consciência

dc.contributor.authorSimoni, Ricardo Francisco [UNESP]
dc.contributor.authorEsteves, Luis Otávio [UNESP]
dc.contributor.authorMiziara, Luiz Eduardo de Paula Gomes
dc.contributor.authorCangiani, Luiz Marciano
dc.contributor.authorAlves, Gustavo Groth Oliveira
dc.contributor.authorRomano, André Luz Pereira
dc.contributor.authorHansen, Paula Úrica
dc.contributor.authorVianna, Pedro Thadeu Galvão [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionFundação CMC
dc.contributor.institutionCMC
dc.date.accessioned2022-04-29T00:49:43Z
dc.date.available2022-04-29T00:49:43Z
dc.date.issued2011-07-01
dc.description.abstractBackground and objective: The constant equilibrium between the plasma and effect site (ke0) is used by pharmacokinetic models to calculate a drug concentration in its site of action (Ce). It would be interesting if Ce of propofol was similar at loss and recovery of consciousness. The objective of this study was to evaluate the clinical performance of two different ke0 (fast = 1.21 min -1, and slow = 0.26 min -1) in relation to Ce during loss and recovery of consciousness using Marsh pharmacokinetic model. Methods: Twenty healthy adult male volunteers participated in this study. In all volunteers propofol was administered as target-controlled infusion, Marsh pharmacokinetic model for fast ke0 and, at a different time, the same pharmacokinetic model with slow ke0 was used. Initially, propofol was infused with a serum target-controlled infusion of 3.0 μg.mL -1. Loss of consciousness and recovery of consciousness were based on response to verbal stimulus. Ce was recorded at the moment of loss and recovery of consciousness. Results: On loss and recovery of consciousness, the Ce for fast ke0 was different (3.64 ± 0.78 and 1.47 ± 0.29 μg.mL -1, respectively, p < 0.0001), while with slow ke0 the Ce was similar (2.20 ± 0.70 and 2.14 ± 0.43 μg.mL -1, respectively, p = 0.5425). Conclusions: Clinically, the slow ke0 (0.26 min -1) incorporated in the Marsh pharmacokinetic model showed better performance than the fast ke0 (1.21 min -1), since the calculated concentration of propofol at the effect site on loss and recovery of consciousness was similar. © 2011 Elsevier Editora Ltda.en
dc.description.affiliationFaculdade de Medicina de Botucatu (UNESP) CET Instituto Penido Burnier CMC
dc.description.affiliationHospital Santa Sofia Ltda. Fundação CMC
dc.description.affiliationFundação Centro Médico de Campinas CET Instituto Penido Burnier CMC
dc.description.affiliationR3 of Instituto Penido Burnier CMC
dc.description.affiliationDepartamento de Anestesiologia da Universidade de Bristol Departamento de Anestesiologia of Faculdade de Medicina de Botucatu da UNESP Júlio de Mesquita Filho
dc.description.affiliationUnespFaculdade de Medicina de Botucatu (UNESP) CET Instituto Penido Burnier CMC
dc.description.affiliationUnespDepartamento de Anestesiologia da Universidade de Bristol Departamento de Anestesiologia of Faculdade de Medicina de Botucatu da UNESP Júlio de Mesquita Filho
dc.format.extent397-408
dc.identifierhttp://dx.doi.org/10.1016/S0034-7094(11)70048-4
dc.identifier.citationRevista Brasileira de Anestesiologia, v. 61, n. 4, p. 397-408, 2011.
dc.identifier.doi10.1016/S0034-7094(11)70048-4
dc.identifier.issn0034-7094
dc.identifier.issn1806-907X
dc.identifier.scopus2-s2.0-80052453326
dc.identifier.urihttp://hdl.handle.net/11449/226507
dc.language.isoeng
dc.language.isopor
dc.relation.ispartofRevista Brasileira de Anestesiologia
dc.sourceScopus
dc.subjectDrug delivery systems
dc.subjectIntraoperative awareness
dc.subjectPharmacokinetics
dc.subjectPropofol, administration and dosage
dc.titleAvaliação Clínica de Duas ke0 no Mesmo Modelo Farmacocinético de Propofol: Estudo da Perda e Recuperação da Consciênciapt
dc.title.alternativeClinical Evaluation of Two Ke0 in the same Pharmacokinetic Propofol Model: Study on Loss and Recovery of Consciousnessen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentAnestesiologia - FMBpt

Arquivos