Logotipo do repositório
 

Publicação:
Determination of furanic aldehydes in sugarcane bagasse by high-performance liquid chromatography with pulsed amperometric detection using a modified electrode with nickel nanoparticles

dc.contributor.authorSilva, José Luiz da[UNESP]
dc.contributor.authorBeluomini, Maísa Azevedo [UNESP]
dc.contributor.authorStradiotto, Nelson Ramos [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-12-07T15:33:49Z
dc.date.available2015-12-07T15:33:49Z
dc.date.issued2015
dc.description.abstractA glassy carbon electrode chemically modified with nickel nanoparticles coupled with reversed-phase chromatography with pulsed amperometric detection was used for the quantitative analysis of furanic aldehydes in a real sample of sugarcane bagasse hydrolysate. Chromatographic separation was carried out in isocratic conditions (acetonitrile/water, 1:9) with a flow rate of 1.0 mL/min, a detection potential of -50 mV vs. Pd, and the process was completed within 4 min. The analytical curves presented limits of detection of 4.0 × 10(-7) mol/L and 4.3 × 10(-7) mol/L, limits of quantification of 1.3 × 10(-6) and 1.4 × 10(-6) mol/L, amperometric sensitivities of 2.2 × 10(6) nA mol/L and 2.7 × 10(6) nA mol/L for furfural and 5-hydroxymethylfurfural, respectively. The values obtained in this sample by the standard addition method were 1.54 ± 0.02 g/kg for 5-hydroxymethylfurfural and 11.5 ± 0.2 g/kg for furfural. The results demonstrate that this new proposed method can be used for the quick detection of furanic aldehydes without the interference of other electroactive species, besides having other remarkable merits that include excellent peak resolution, analytical repeatability, sensitivity, and accuracy.en
dc.description.affiliationInstitute of Chemistry, São Paulo State University - UNESP, Campus Araraquara, Department of Analytical Chemistry, Jardim Quitandinha, Araraquara, SP, Brazil.
dc.description.affiliationUnespInstitute of Chemistry, São Paulo State University - UNESP, Campus Araraquara, Department of Analytical Chemistry, Jardim Quitandinha, Araraquara, SP, Brazil.
dc.identifierhttp://dx.doi.org/10.1002/jssc.201500253
dc.identifier.citationJournal Of Separation Science, 2015.
dc.identifier.doi10.1002/jssc.201500253
dc.identifier.issn1615-9314
dc.identifier.lattes0072173018005712
dc.identifier.pubmed26178531
dc.identifier.urihttp://hdl.handle.net/11449/131318
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofJournal Of Separation Science
dc.relation.ispartofsjr0,795
dc.rights.accessRightsAcesso restrito
dc.sourcePubMed
dc.subjectElectrochemical detectionen
dc.subjectFurfuralen
dc.subjectHydroxymethylfurfuralen
dc.subjectNickel nanoparticlesen
dc.subjectSugarcane bagasseen
dc.titleDetermination of furanic aldehydes in sugarcane bagasse by high-performance liquid chromatography with pulsed amperometric detection using a modified electrode with nickel nanoparticlesen
dc.typeArtigo
dcterms.rightsHolderWiley-Blackwell
dspace.entity.typePublication
unesp.author.lattes0072173018005712
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos