Publicação: Analysis of fluoxetine and norfluoxetine in human plasma by HPLC-UV using a high purity C18 silica-based SPE sorbent
dc.contributor.author | Nazario, Carlos Eduardo Domingues | |
dc.contributor.author | Lima Gomes, Paulo Clairmont Feitosa de [UNESP] | |
dc.contributor.author | Lancas, Fernando Mauro | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2015-05-15T13:30:21Z | |
dc.date.available | 2015-05-15T13:30:21Z | |
dc.date.issued | 2014 | |
dc.description.abstract | This paper reports on the development and validation of a simple and sensitive method that uses solid phase extraction (SPE) and liquid chromatography with ultraviolet detection to analyze fluoxetine (FLX) and norfluoxetine (NFLX) in human plasma samples. A lab-made C18 SPE phase was synthesized by using a sol–gel process employing a low-cost silica precursor. This sorbent was fully characterized by nuclear magnetic resonance (NMR), Fourier-transform infrared spectroscopy (FT-IR), and scanning electron microscopy (SEM) to check the particles' shape, size and C18 functionalization. The lab-made C18 silica was used in the sample preparation step of human plasma by the SPE-HPLC-UV method. The method was validated in the 15 to 500 ng mL 1 range for both FLX and NFLX using a matrix matched curve. Detection limits of 4.3 and 4.2 ng mL 1 were obtained for FLX and NFLX, respectively. The repeatability and intermediary precision achieved varied from 7.6 to 15.0% and the accuracy ranged from 14.9 to 9.1%. The synthesized C18 sorbent was compared to commercial C18 sorbents. The average recoveries were similar (85–105%), however the lab-made C18 silica showed fewer interfering peaks in the chromatogram. After development and validation, the method using the lab-made C18 SPE was applied to plasma samples of patients under FLX treatment (n ¼ 6). The concentrations of FLX and NFLX found in the samples varied from 46.8–215.5 and 48.0–189.9 ng mL 1 , respectively. | en |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Instituto de Química de Araraquara, Araraquara, Rua Professor Francisco Degni, Departamento de Química Analítica, Jardim Quitandinha, CEP 14800060, SP, Brasil | |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Instituto de Química de Araraquara, Araraquara, Rua Professor Francisco Degni, Departamento de Química Analítica, Jardim Quitandinha, CEP 14800060, SP, Brasil | |
dc.format.extent | 4181-4187 | |
dc.identifier | http://pubs.rsc.org/en/Content/ArticleLanding/2014/AY/c4ay00117f#!divAbstract | |
dc.identifier.citation | Analytical Methods, v. 6, n. 12, p. 4181-4187, 2014. | |
dc.identifier.doi | 10.1039/c4ay00117f | |
dc.identifier.issn | 1759-9660 | |
dc.identifier.lattes | 49857977635051 | |
dc.identifier.uri | http://hdl.handle.net/11449/123523 | |
dc.language.iso | eng | |
dc.relation.ispartof | Analytical Methods | |
dc.relation.ispartofjcr | 2.073 | |
dc.relation.ispartofsjr | 0,619 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Currículo Lattes | |
dc.title | Analysis of fluoxetine and norfluoxetine in human plasma by HPLC-UV using a high purity C18 silica-based SPE sorbent | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.lattes | 49857977635051 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |