Logotipo do repositório
 

Publicação:
Avaliação comparativa entre as telerradiografias cefalométricas laterais convencional, digital e geradas por tomografia computadorizada por aquisição volumétrica – cone beam

dc.contributor.advisorBertoz, Francisco Antonio [UNESP]
dc.contributor.authorJunqueira, José Luiz Cintra [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:33:23Z
dc.date.available2014-06-11T19:33:23Z
dc.date.issued2007-08-30
dc.description.abstractO objetivo nesta pesquisa foi analisar os resultados obtidos comparativamente entre as telerradiografias cefalométricas laterais convencional, digital e as geradas pela tomografia computadorizada por aquisição volumétrica Cone Beam (CBTC). Foram realizadas distintamente as três tomadas radiográficas em 35 pacientes que estavam compreendidos na faixa etária de 12 a 14 anos. Foram utilizados dois programas específicos para a realização das análises cefalométricas de Rickets, McNamara e Jarabak, sendo utilizadas medidas lineares e angulares dos traçados. Apenas no traçado de Jarabak, foram utilizadas duas medidas lineares, para todas as outras, foi usada somente uma mensuração. Quatro tipos de exames radiográficos associados aos programas de análise cefalométrica foram utilizados. Por considerar o melhor resultado nos valores obtidos, a variável de referência foi a aquisição volumétrica CBTC em norma ortogonal, sendo comparado com os outros métodos. Verificou-se que os resultados obtidos pelas medidas angulares apresentaram menor variabilidade, enquanto as medidas lineares somente no traçado cefalométrico de McNamara obteve-se similaridade das variáveis. Observou-se que as técnicas radiográficas cefalométricas laterais convencionais apresentaram as maiores discrepâncias em relação à variável de referência. As análises cefalométricas realizadas pelo mesmo programa obtiveram os melhores resultados. Concluiu-se que para a obtenção de análises cefalométricas mais fidedignas deve-se utilizar um mesmo programa de avaliação e a tecnologia digital, principalmente a aquisição volumétrica CBTC em norma ortogonal e a telerradiografia cefalométrica lateral digital.pt
dc.description.abstractThe aim of this research was to analyze the results obtained comparatively among digital and conventional lateral cephalometric teleradiographies and the ones generated by Cone Beam volume computerized tomography (CBCT). Three distinct radiographies were performed in 35 patients in a 12 to 14 year-old group. Two specific programs were used to perform the cephalometric analysis according to Ricketts, McNamara and Jarabak, using linear and angular measurements of tracings. Two linear measurements were used just for Jarabak’s tracing, for all the others only one measurement was used. Four types of radiographic exams associated to the cephalometric analysis program were used. For considering the best result in the obtained values, the variable of reference was the volume acquisition (CBCT) being compared to the other methods. It was verified that the results obtained by angular measurements presented less variability, while the linear measurements only in McNamara’s cephalometric tracing presented similarity of variables. It was observed that the conventional lateral cephalometric radiography techniques presented bigger discrepancies in relation to the variable of reference. The cephalometric analysis performed by the same evaluation program had the best results. It was concluded that in order to obtain more reliable cephalometric analysis, one should use the same evaluation program and digital technology, particularly the volume acquisition (CBCT) in octagonal norm and digital lateral cephalometric teleradiography.en
dc.format.extent106 f. : il. + 1 CD-ROM
dc.identifier.aleph000550206
dc.identifier.capes33004021011P0
dc.identifier.citationJUNQUEIRA, José Luiz Cintra. Avaliação comparativa entre as telerradiografias cefalométricas laterais convencional, digital e geradas por tomografia computadorizada por aquisição volumétrica – cone beam. 2007. 106 f. Tese (doutorado) - Universidade Estadual Paulista, Faculdade de Odontologia de Araçatuba, 2007.
dc.identifier.filejunqueira_jlc_dr_araca.pdf
dc.identifier.urihttp://hdl.handle.net/11449/104521
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.sourceAleph
dc.subjectRadiografiapt
dc.subjectOrtodontiapt
dc.subjectTomografia computadorizada por raios xpt
dc.subjectCircunferência cranianapt
dc.subjectRadiographyen
dc.subjectTomography, X-Ray Computeden
dc.subjectCephalometryen
dc.subjectOrthodonticsen
dc.titleAvaliação comparativa entre as telerradiografias cefalométricas laterais convencional, digital e geradas por tomografia computadorizada por aquisição volumétrica – cone beampt
dc.typeTese de doutoradopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.graduateProgramOdontologia - FOApt
unesp.knowledgeAreaOrtodontiapt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
junqueira_jlc_dr_araca.pdf
Tamanho:
576.86 KB
Formato:
Adobe Portable Document Format