Publicação:
Stress analysis in oral obturator prostheses, part II: photoelastic imaging

dc.contributor.authorPesqueira, Aldieris Alves [UNESP]
dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorFreitas da Silva, Emily Vivianne [UNESP]
dc.contributor.authorHaddad, Marcela Filie
dc.contributor.authorMoreno, Amalia [UNESP]
dc.contributor.authorZahoui, Abbas
dc.contributor.authorSantos, Daniela Micheline dos [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionFed Univ Alfenas Unifal
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2015-03-18T15:55:23Z
dc.date.available2015-03-18T15:55:23Z
dc.date.issued2014-06-01
dc.description.abstractIn part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis. (C) 2014 Society of Photo-Optical Instrumentation Engineers (SPIE).en
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Aracatuba, SP, Brazil
dc.description.affiliationFed Univ Alfenas Unifal, Sch Dent, Dept Restorat Dent, BR-37130000 Alfenas, MG, Brazil
dc.description.affiliationUni Sagrado Coracao, Fac Dent, Dept Oral Biol, BR-17011160 Bauru, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Aracatuba, SP, Brazil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.format.extent5
dc.identifierhttp://dx.doi.org/10.1117/1.JBO.19.6.066012
dc.identifier.citationJournal Of Biomedical Optics. Bellingham: Spie-soc Photo-optical Instrumentation Engineers, v. 19, n. 6, 5 p., 2014.
dc.identifier.doi10.1117/1.JBO.19.6.066012
dc.identifier.issn1083-3668
dc.identifier.lattes9719883814872582
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.urihttp://hdl.handle.net/11449/117185
dc.identifier.wosWOS:000340432900019
dc.language.isoeng
dc.publisherSpie-soc Photo-optical Instrumentation Engineers
dc.relation.ispartofJournal Of Biomedical Optics
dc.relation.ispartofjcr2.367
dc.relation.ispartofsjr0,918
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectphotoelastic imagingen
dc.subjectdental implanten
dc.subjectpalatal obturatorsen
dc.subjectmaxillofacial prosthesisen
dc.titleStress analysis in oral obturator prostheses, part II: photoelastic imagingen
dc.typeArtigo
dcterms.rightsHolderSpie-soc Photo-optical Instrumentation Engineers
dspace.entity.typePublication
unesp.author.lattes9719883814872582
unesp.author.lattes2336450644149867[1]
unesp.author.orcid0000-0002-3800-3050[2]
unesp.author.orcid0000-0003-3020-5253[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos