Increasing fatigue resistance of AISI 4340 steel by nitrogen plasma ion-implantation

dc.contributor.authorVoorwald, H. J. C. [UNESP]
dc.contributor.authorBonora, R. G.
dc.contributor.authorOliveira, V. M. C. A. [UNESP]
dc.contributor.authorCioffi, M. O. H. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionMetrolab Calibracoes Ltda
dc.date.accessioned2019-10-04T12:15:59Z
dc.date.available2019-10-04T12:15:59Z
dc.date.issued2019-01-01
dc.description.abstractFailures in structural components due to cyclic loading are associated with materials surface damage. Coatings deposited by different surface processes are more or less effective to improve the degradation resistance of diverse elements. The present study aim is to analyze plasma immersion ion implantation (PHI) effect on axial fatigue strength, corrosion and wear resistance of AISI 4340 steel. Experimental results indicate an axial fatigue strength increase for 1, 2 and 3 h of treatment. PIII treatment was not effective to protect AISI 4340 steel against environmental aggressive action. In abrasive wear tests, lower pin mass reduction was observed due to superficial treatment.en
dc.description.affiliationUniv Estadual Paulista, Fatigue & Aeronaut Mat Res Grp, UNESP, Av Ariberto Pereira da Cunha 333, BR-12516410 Guaratingueta, SP, Brazil
dc.description.affiliationMetrolab Calibracoes Ltda, Rua Francisco Goncalves Fonseca 120, BR-12238575 Sao Jose Dos Campos, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Fatigue & Aeronaut Mat Res Grp, UNESP, Av Ariberto Pereira da Cunha 333, BR-12516410 Guaratingueta, SP, Brazil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdCNPq: 303832/2014-2
dc.description.sponsorshipIdFAPESP: 2011/00508-9
dc.format.extent490-499
dc.identifierhttp://dx.doi.org/10.1016/j.engfailanal.2019.06.018
dc.identifier.citationEngineering Failure Analysis. Oxford: Pergamon-elsevier Science Ltd, v. 104, p. 490-499, 2019.
dc.identifier.doi10.1016/j.engfailanal.2019.06.018
dc.identifier.issn1350-6307
dc.identifier.urihttp://hdl.handle.net/11449/184694
dc.identifier.wosWOS:000484364400041
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofEngineering Failure Analysis
dc.rights.accessRightsAcesso abertopt
dc.sourceWeb of Science
dc.subjectPlasma immersion ion implantation
dc.subjectAxial fatigue
dc.subjectResidual stress
dc.subjectCorrosion
dc.subjectWear
dc.titleIncreasing fatigue resistance of AISI 4340 steel by nitrogen plasma ion-implantationen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia e Ciências, Guaratinguetápt

Arquivos