dc.description.abstractPurpose: The aim of this study was to evaluate the effect of sealing agents on preload maintenance of screw joints. Materials and Methods: A total of four groups (n = 10 in each group) of abutment/implant systems, including external hexagon implants and antirotational UCLA abutments with a metallic collar in cobalt-chromium alloy, were assessed. In the control group (CG), no sealing agent was used at the abutment screw/implant interface. In the other groups, three different sealing agents were used at the abutment screw/implant interface: anaerobic sealing agent for medium torque (ASMT), anaerobic sealing agent for high torque (ASHT), and cyanoacrylate-based bonding agent (CYAB). All abutments were attached to the implants at 32 ± 1 N.cm. After 48 ± 2 hours of initial tightening, loosing torque (detorque) was measured using a digital torque wrench. Data were analyzed using Shapiro-Wilk, Wilcoxon, and Kruskal-Wallis tests, at 5% level of significance. Results: In the CG and ASMT groups, detorque was lower than the insertion torque (24.6 ± 1.5 N.cm and 24.3 ± 1.1 N.cm, respectively). In the ASHT and CYAB groups, mean detorque increased in comparison to the insertion torque (51.0 ± 7.4 N.cm and 47.7 ± 15.1 N.cm, respectively). Conclusion: The ASHT was more efficient than the other sealing agents, increasing the remaining preload (detorque value) 58.88%. Although the cyanoacrylate-based bonding agent also generated high detorque values, the high standard deviation suggested its lower reliability.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University (UNESP)
dc.description.affiliationDepartment of Dentistry Ingá Faculty (UNINGá)
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University (UNESP)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipIdCAPES: 166000/2013-2
dc.format.extent123-126
dc.identifierhttp://dx.doi.org/10.11607/jomi.5576
dc.identifier.citationInternational Journal of Oral and Maxillofacial Implants, v. 33, n. 1, p. 123-126, 2018.
dc.identifier.doi10.11607/jomi.5576
dc.identifier.issn0882-2786
dc.identifier.scopus2-s2.0-85041818563
dc.identifier.urihttp://hdl.handle.net/11449/175863
dc.language.isoeng
dc.relation.ispartofInternational Journal of Oral and Maxillofacial Implants
dc.relation.ispartofsjr1,576
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.subjectDetorque
dc.subjectImplant-supported restorations
dc.subjectPreload
dc.subjectScrew joint
dc.titleEfficacy of sealing agents on preload maintenance of screw-retained implant-supported prosthesesen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos