Publicação:
Piezoelectric transducers assessed by the pencil lead break for impedance-based structural health monitoring

Nenhuma Miniatura disponível

Data

2015-02-01

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Ieee-inst Electrical Electronics Engineers Inc

Tipo

Artigo

Direito de acesso

Acesso restrito

Resumo

The pencil lead break (PLB) is a well-known method for characterizing acoustic emission sensors. In this paper, we analyze the effectiveness of this method in characterizing piezoelectric transducers for structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique. Tests were carried out on aluminum beams of different sizes, and two types of transducers were considered: 1) lead zirconate titanate ceramics and 2) macrofiber composite devices. The experimental results indicate a clear relationship between the variation in the electrical impedance signature of the transducer and power spectral density obtained with the PLB method. Therefore, the PLB can be a simple and effective method for assessing the sensitivity of transducers for damage detection in SHM systems based on the EMI technique.

Descrição

Idioma

Inglês

Como citar

Ieee Sensors Journal. Piscataway: Ieee-inst Electrical Electronics Engineers Inc, v. 15, n. 2, p. 693-702, 2015.

Itens relacionados

Unidades

Departamentos

Cursos de graduação

Programas de pós-graduação