dc.identifierhttp://vcot.schattauer.de/en/contents/archivestandard/issue/2169/manuscript/23786.html
dc.identifier.citationVeterinary And Comparative Orthopaedics And Traumatology. Stuttgart: Schattauer Gmbh-verlag Medizin Naturwissenschaften, v. 28, n. 1, p. 25-29, 2015.
dc.identifier.issn0932-0814
dc.identifier.urihttp://hdl.handle.net/11449/128409
dc.description.abstractObjectives: To evaluate the influence on the kinetic and temporospatial parameters of calibration protocols with point and step techniques for a pressure-sensing walkway.Methods: Nine Labrador dogs were used. Two protocols of point calibration technique (Cl and C2) and eight protocols of step calibration technique (C3 to C10) were performed. In Cl, weight was added to a stool to match the body mass of each dog. In C2, weight was added to the stool to match a 46.1 kg person. The other eight calibration protocols represented combinations of the following factors: 46.1 kg and 96.1 kg persons, barefoot or wearing sneakers, and stepping onto the platform with one or two feet.Results: The calibration protocols did not affect the temporospatial variables or percentages of body weight (%BW) distribution. Significant differences were found in both PVI (peak vertical force) and VI (vertical impulse) between barefoot versus wearing sneakers, 46.1 kg versus 96.1 kg person, and stepping onto the platform with one foot versus two feet. When comparing Cl with other protocols, significant differences were observed in PVF and VI for both forelimbs and hindlimbs. When comparing C2 with other protocols, significant differences were observed in PVF and VI for both forelimbs and hindlimbs in all protocols.Clinical significance: The PVF and VI were influenced by the calibration protocol used, but the %BW distribution and temporospatial parameters were not. Using the same calibration protocol for all dogs within the same group eliminated the variability of the kinetic data caused by the calibration.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent25-29
dc.language.isoeng
dc.publisherSchattauer Gmbh-verlag Medizin Naturwissenschaften
dc.relation.ispartofVeterinary And Comparative Orthopaedics And Traumatology
dc.sourceWeb of Science
dc.subjectPressure platformen
dc.subjectTekscanen
dc.subjectCalibrationen
dc.titleInfluence of calibration protocols for a pressure-sensing walkway on kinetic and temporospatial parametersen
dc.typeArtigo
dcterms.licensehttp://vcot.schattauer.de/en/advertising/advertising.html
dcterms.rightsHolderSchattauer Gmbh-verlag Medizin Naturwissenschaften
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniv Fed Rural Amazônia (UFRA)
dc.description.affiliationUniversidade Estadual Paulista (UNESP) - School of Veterinary Medicine and Animal Science, Department of Veterinary Surgery and Anesthesiology, Botucatu, SP, Brazil
dc.description.affiliationUniversidade Federal Rural da Amazônia, Instituto de Saúde e Produção Animal, Belém do Pará, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista (UNESP) - School of Veterinary Medicine and Animal Science, Department of Veterinary Surgery and Anesthesiology, Botucatu, SP, Brasil
dc.identifier.doi10.3415/VCOT-14-05-0081
dc.identifier.wosWOS:000348489700006
dc.rights.accessRightsAcesso aberto
dc.description.sponsorshipIdCAPES: 21/2009
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária e Zootecnia, Botucatupt
dc.identifier.lattes1497433265390194
dc.identifier.lattes8560913137958850
dc.identifier.orcid0000-0002-9211-4093
unesp.author.lattes1497433265390194
unesp.author.lattes8560913137958850
unesp.author.orcid0000-0002-1406-9979[7]
unesp.author.orcid0000-0002-9211-4093[2]
unesp.author.orcid0000-0001-6639-037X[5]
dc.relation.ispartofjcr0.872
dc.relation.ispartofsjr0,726
Localize o texto completo

Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record