Show simple item record

dc.contributor.authorTanomaru-Filho, M. [UNESP]
dc.contributor.authorJorge, E. G. [UNESP]
dc.contributor.authorTanomaru, Juliane Maria Guerreiro [UNESP]
dc.contributor.authorGonçalves, Marcelo [UNESP]
dc.date.accessioned2014-05-20T13:45:33Z
dc.date.available2014-05-20T13:45:33Z
dc.date.issued2008-01-01
dc.identifierhttp://dx.doi.org/10.1111/j.1365-2591.2007.01309.x
dc.identifier.citationInternational Endodontic Journal. Oxford: Blackwell Publishing, v. 41, n. 1, p. 50-53, 2008.
dc.identifier.issn0143-2885
dc.identifier.urihttp://hdl.handle.net/11449/16036
dc.description.abstractAim To evaluate the radiopacity of calcium hydroxide-based root canal sealers (Acroseal, Sealapex and Sealer 26), a glass-ionomer-based sealer (Activ GP Sealer) and a zinc oxide and eugenol-based sealer (Intrafill).Methodology Five disc-shaped specimens (10 x 1 mm) were fabricated from each material, according to the International Organization for Standardization (ISO) 6876/2001 standard. After setting of the materials, radiographs were taken using occlusal films and a graduated aluminum step-wedge varying from 2 to 16 mm in thickness. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses s(-1) and distance of 33.5 cm. The radiographs were digitized and the radiopacity compared with that of the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were submitted to ANOVA and Tukey test.Results Intrafill was the most radiopaque material (7.67 mm Al) followed by Sealer 26 (6.33 mm Al), Sealapex (6.05 mm Al) and Acroseal (4.03 mm Al). Activ GP was the least radiopaque material (1.95 mm Al, P < 0.05).Conclusions The sealers evaluated in this study had different radiopacities. However, except for the glass-ionomer-based sealer, all materials had radiopacity values above the minimum recommended by the ISO standard.en
dc.format.extent50-53
dc.language.isoeng
dc.publisherBlackwell Publishing
dc.relation.ispartofInternational Endodontic Journal
dc.sourceWeb of Science
dc.subjectradiologyen
dc.subjectradiopacityen
dc.subjectroot canal filling materialsen
dc.titleEvaluation of the radiopacity of calcium hydroxide- and glass-ionomer-based root canal sealersen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderBlackwell Publishing
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.description.affiliationUniv Estadual Paulista, Dept Restorat Dent, São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Araraquara Dent Sch, Dept Radiol, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Restorat Dent, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Araraquara Dent Sch, Dept Radiol, São Paulo, Brazil
dc.identifier.doi10.1111/j.1365-2591.2007.01309.x
dc.identifier.wosWOS:000252260800005
dc.rights.accessRightsAcesso restrito
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquarapt
dc.identifier.lattes1067437159861527
unesp.author.lattes1067437159861527
unesp.author.orcid0000-0002-2574-4706[1]
unesp.author.orcid0000-0003-0446-2037[3]
dc.relation.ispartofjcr3.015
dc.relation.ispartofsjr1,791
Localize o texto completo

Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record