An improved mouth-piece to prevent environmental contamination during radioaerosol inhalation procedures

Nenhuma Miniatura disponível

Data

1998-10-01

Autores

Braga, FJHN
Souza, J. F.
Trad, C. S.
Santos, A. C.
Netto, T. G.
Elias, J.
Hindie, E.
Iazigi, N.

Título da Revista

ISSN da Revista

Título de Volume

Editor

Lippincott Williams & Wilkins

Resumo

The literature suggests that environmental contamination is common during labeled aerosol inhalation procedures in nuclear medicine. We have tested an adherent mask to prevent environmental contamination in 70 procedures. Two groups of patients were evaluated, Group 1 (60 inhalation cases in which the mask was used) presented no environmental contamination in 95% of the procedures (means of 553 dpm and 596 dpm before and after inhalation, p > 0.05, mean of the differences before/after inhalation 6.95, SD = 21.2 dpm) and the only 3 cases in which contamination did occur concerned bearded men; Group 2 (10 inhalation cases in which the mask was not used) showed large increases of environmental radioactive levels in 70% of the procedures (means of 601 dpm and 2,756 dpm before and after inhalation, p < 0.05, mean of the differences 3,066, SD = 2,98 dpm), We conclude that such a mask is very helpful in avoiding environmental contamination during radioaerosol inhalation procedures.

Descrição

Palavras-chave

aerosols, inhalation, contamination, environmental, radiation protection

Como citar

Health Physics. Philadelphia: Lippincott Williams & Wilkins, v. 75, n. 4, p. 424-427, 1998.