Show simple item record

dc.contributor.authorFonseca, Patrícia C. de F
dc.contributor.authorAlmeida, Eduardo A. de [UNESP]
dc.contributor.authorPassini, Roberta
dc.date.accessioned2014-05-20T13:14:26Z
dc.date.available2014-05-20T13:14:26Z
dc.date.issued2011-12-01
dc.identifierhttp://dx.doi.org/10.1590/S0100-69162011000600002
dc.identifier.citationEngenharia Agrícola. Associação Brasileira de Engenharia Agrícola, v. 31, n. 6, p. 1044-1051, 2011.
dc.identifier.issn0100-6916
dc.identifier.urihttp://hdl.handle.net/11449/1909
dc.description.abstractDentre os materiais de construção utilizados nas instalações rurais, merecem destaque as coberturas, pois são grandes responsáveis pelo conforto térmico, influenciando no balanço térmico no interior das instalações. Este trabalho objetivou avaliar a influência das coberturas sobre a entalpia (H), Carga Térmica Radiante (CTR) e no Índice de Temperatura de Globo Negro e Umidade (ITGU), em abrigos individuais para bezerros leiteiros. O delineamento foi o inteiramente casualizado com três tratamentos: Z - telha de zinco; CA - telha de cimento amianto, e CAB - telha de cimento amianto pintada de branco na face superior. As médias foram comparadas pelo teste de Scott Knott, a 1% de probabilidade. Os resultados mostraram que não houve diferença estatística entre os tratamentos (P<0,01) e o ambiente externo, para a H. Para a CTR, houve diferença estatística entre todos os tratamentos, em que CAB demonstrou menor CTR, 489,28 W m-², seguido do tratamento CA, 506,72 W m-², e Z com maior valor de CTR, 523,55 W m-². Para o ITGU, observaram-se menores valores para CAB (76,8) e CA (77,4), diferindo-se, significativamente do Z, que obteve maior valor (81,6). As telhas com pintura branca em sua face superior promoveram menor CTR e menor ITGU, favorecendo o ambiente térmico da instalação.pt
dc.description.abstractAmong the building materials used in rural facilities, roofs are noteworthy for being largely responsible for thermal comfort, influencing the thermal balance within the shelter. This study aimed to evaluate the influence of roof on the Enthalpy (H), Thermal Load of Radiation (TLR), and Black Globe Temperature and Humidity Index (BGHI) in individual shelters for dairy calves. The design was completely randomized with three treatments: Z - zinc tile, AC - asbestos-cement tile and ACW - asbestos-cement tile painted white on the upper side. The averages were compared by the Scott Knott test at 1% probability. The results showed no statistical difference between treatments (P<0.01) and the external environment for H. For TLR, there was statistical difference among all treatments, where ACW showed the lowest TLR, 489.28 W m-2, followed by AC with 506.72 W m-2 and Z with the highest TLR, 523.55 W m-2. For BGHI, the lowest values were observed for ACW (76.8) and AC (77.4), differing significantly from Z, which obtained the highest value (81.6). The tiles with white paint on the upper side promoted the lowest TLR and the lowest BGHI, favoring the thermal environment in the shelter.en
dc.format.extent1044-1051
dc.language.isoeng
dc.publisherAssociação Brasileira de Engenharia Agrícola (SBEA)
dc.relation.ispartofEngenharia Agrícola
dc.sourceSciELO
dc.subjectíndices térmicospt
dc.subjectmateriais de construção e tipo de coberturapt
dc.subjectthermal indicesen
dc.subjectconstruction materials and type of roofen
dc.titleThermal comfort indices in individual shelters for dairy calves with different types of roofsen
dc.title.alternativeAmbiente térmico no interior de abrigos individuais para bezerros com a utilização de diferentes tipos de coberturaspt
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/eagri/paboutj.htm
dc.contributor.institutionUniversidade Estadual de Goiás (UEG)
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.description.affiliationUniversidade Estadual de Goiás
dc.description.affiliationUNESP Faculdade de Ciências Agrárias e Veterinárias
dc.description.affiliationUnespUNESP Faculdade de Ciências Agrárias e Veterinárias
dc.identifier.doi10.1590/S0100-69162011000600002
dc.identifier.scieloS0100-69162011000600002
dc.identifier.wosWOS:000299060700003
dc.rights.accessRightsAcesso aberto
dc.identifier.fileS0100-69162011000600002.pdf
dc.relation.ispartofjcr0.387
dc.relation.ispartofsjr0,305
Localize o texto completo

Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record