Intrapulpar temperature during continuous CO2 laser irradiation in human molars: An in vitro study
Abstract
To establish safety parameters, we in vitro studied the increase in intrapulpal temperature caused by the use of a cw CO2 laser. A thermistor was implanted in the inner part of the pulpal chamber of 25 human lower third molars to measure the intrapulpal temperature produced by laser powers between 2-10 W and exposure times of 0.5-25.0 s. The Pearson linear correlation factor applied to the measured values showed there is a direct relationship between the independent variable and the applied power. A variance analysis produced the linear regression equation: T=1.10+(0.127)E where T is the temperature and E the energy. The results showed that, with a power of 4 W and maximum exposure time of 2.5 s (10 J) and a power density of 12738.85 W cm-2, there will be no damaging reactions affecting the pulpal tissues.
How to cite this document
Keywords
Language
Collections

Related items
Showing items related by title, author, creator and subject.
-
Application of pulsed laser ND: YAG in superduplex steel uns S 32750: Autogenous laser welding, laser welding with refusion process by laser and hybrid welding (laser/Gtaw)
Da Silva Crespo, Gillian; Moraes e Videira, Arthur
; Ventrella, Vicente Afonso
(Nd:YAG Lasers: Technology and Applications, 2020) [Capítulo de livro]
The families of duplex and superduplex steels were developed to serve sectors that demand steels with extreme mechanical capacity and good corrosion resistance. Such characteristics are due to their structure being composed ... -
Morphologic changes and removal of debris on apical dentin surfaces after Nd : YAG laser and diode laser irradiation
Moura-Netto, Cacio de; Maranho de Moura, Abilio Albuquerque; Davidowicz, Harry; Aun, Carlos Eduardo; Santos Antonio, Miriam Porcel do (Photomedicine And Laser Surgery, 2008) [Artigo]
Objective: To verify the effects of laser energy on intracanal dentin surfaces, by analyzing the morphologic changes and removal of debris in the apical third of 30 extracted human teeth, prepared and irradiated with the ... -
Effect of Er:YAG laser and diamond drill on hybrid layer morphology obtained with self-etch adhesive: analysis by SEM and confocal laser scanning microscopy (CLSM)
Gonçalves, Aline de Oliveira; Kubo, Cinthia Sawamura
; Oliveira Júnior, Osmir Batista de
; Campos, Edson Alves
; Andrade, Marcelo Ferrarezi de
(RSBO. Revista Sul-Brasileira de Odontologia, 2014) [Artigo]
This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives ...