Effects of Plasma Immersion Ion Implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy
Date
2006-09-01Type
Conference paper

View/ Open
Access rights
Open access 

Metadata
Show full item recordAbstract
Ti-6Al-4V samples have been treated by PHI processing at different temperatures (400-800°C), treatment time (30-150 min) and plasma potential (100 and 420 V). Hardness measurements results showed an enhancement of the hardness for all implanted samples. XRD results detected the Ti 2N phase and the best corrosion resistance was found for the samples processed at higher temperature and lower PIII time.
How to cite this document
Silva, Leide Lili G. da et al. Effects of Plasma Immersion Ion Implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy. Brazilian Journal of Physics, v. 36, n. 3 B, p. 990-993, 2006. Available at: <http://hdl.handle.net/11449/69067>.