Variable speed refrigeration system with HPF input rectifier stage
Abstract
This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.
How to cite this document
Keywords
Language

Related items
Showing items related by title, author, creator and subject.
-
Um novo sistema de refrigeração com controle de temperatura, compressor aberto, máquina de indução trifásica com velocidade variável e correção ativa do fator de potência do estágio de entrada
Leandro, Eduardo(Universidade Estadual Paulista (Unesp), 2006) [Dissertação de mestrado]
Este trabalho apresenta uma nova proposta para sistema de refrigeração com controle dinâmico de temperatura, operando com estrutura de compressor aberto, acionado por motor de indução trifásico com velocidade variável, e ... -
Coeficiente de operación de un sistema formado por un refrigerador doméstico acoplado a un acumulador de agua caliente para la recuperación de energía
Souza, Luís M.P.; Scalon, Vicente L.
; Padilha, Alcides
(Informacion Tecnologica, 2012) [Artigo]
An experimental apparatus containing a domestic refrigerator coupled to a vertical hot water storage tank was used for energy recovery. The original condenser of the refrigerator was maintained, but modified with a concentric ... -
HPF boost interleaved operating in discontinuous conduction mode for trolleybus application
Gonçalves, Flávio A. S.; Canesin, Carlos A.
; Melo, Guilherme A.
; De Freitas, Luiz C. G.
(2009 Brazilian Power Electronics Conference, COBEP2009, 2009) [Trabalho apresentado em evento]
This paper deals with results of a research and development (R&D) project in cooperation with Electric Power Distribution Company in São Paulo (Brazil) regarding the development and experimental analysis of a new concept ...