Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
Author
Date
2011-11-01Type

View/ Open
Access rights

Metadata
Show full item recordAbstract
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.
How to cite this document
Keywords
Language

Related items
Showing items related by title, author, creator and subject.
-
Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling
Assunção, Wirley Goncalves; Barão, Valentim Adelino Ricardo
; Delben, Juliana Aparecida
; Gomes, Érica Alves
; Garcia, Idelmo Rangel
(Journal of Prosthodontic Research, 2011) [Artigo]
Purpose: The aim of this study was to evaluate the effect of different levels of unilateral angular misfit on preload maintenance of retention screws of single implant-supported prostheses submitted to mechanical cycling. ... -
Evaluation of transfer impressions for osseointegrated implants at various angulations
Assunção, Wirley Goncalves; Gennari Filho, Humberto
; Zaniqueili, Osvaldo (Implant Dentistry, 2004) [Artigo]
The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under ... -
Accuracy of impression techniques for implants. Part 1 - Influence of transfer copings surface abrasion
Assunção, Wirley Goncalves; Cardoso, Alessandra; Gomes, Erica Alves
; Tabata, Lucas Fernando
; Santos, Paulo Henrique dos
(Journal of Prosthodontics, 2008) [Artigo]
Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = ...