Influence of the elevation of the left ventricular diastolic pressure on the values of the first temporal derivative of the ventricular pressure (dP/dt)
dc.contributor.author | Okoshi, Katashi [UNESP] | |
dc.contributor.author | Fioretto, José Roberto [UNESP] | |
dc.contributor.author | Bonatto, Rossano César [UNESP] | |
dc.contributor.author | Tornero, Maria Teresinha Trovarelli [UNESP] | |
dc.contributor.author | Tucci, Paulo José [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:32:57Z | |
dc.date.available | 2014-05-20T13:32:57Z | |
dc.date.issued | 1999-07-01 | |
dc.description.abstract | PURPOSE: To assess the effects of the elevation of the left ventricular end-diastolic pressure (LVEDP) on the value of the 1st temporal derivative of the ventricular pressure (dP/dt). METHODS: Nineteen anesthetized dogs were studied. The dogs were mechanically ventilated and underwent thoracotomy with parasympathetic nervous system block. The LVEDP was controlled with the use of a perfusion circuit connected to the left atrium and adjusted to the height of a reservoir. The elevation of the LVEDP was achieved by a sudden increase in the height of a reservoir filled with blood. Continuous recordings of the electrocardiogram, the aortic and ventricular pressures and the dP/dt were performed. RESULTS: Elevation of the LVEDP did not result in any variation of the heart rate (167±16.0bpm, before the procedure; 167±15.5bpm, after the procedure). All the other variables assessed, including systolic blood pressure (128±18.3mmHg and 150±21.5mmHg), diastolic blood pressure (98±16.9mmHg and 115±19.8mmHg), LVEDP (5.5±2.49 and 9.3±3.60mmHg), and dP/dt (4,855 ± 1,082 mmHg/s and 5,149±1,242mmHg/s) showed significant increases following the expansion of the ventricular cavity. Although the elevation of the dP/dt was statistically significant, 6 dogs curiously showed a decrease in the values of dP/dt. CONCLUSION: Sudden elevation of the LVEDP resulted in increased values of dP/dt; however, in some dogs, this response was not uniform. | en |
dc.description.affiliation | Universidade Estadual de São Paulo Faculdade de Medicina de Botucatu | |
dc.format.extent | 42-46 | |
dc.identifier | http://dx.doi.org/10.1590/S0066-782X1999000700004 | |
dc.identifier.citation | Arquivos Brasileiros de Cardiologia. Sociedade Brasileira de Cardiologia - SBC, v. 73, n. 1, p. 42-46, 1999. | |
dc.identifier.doi | 10.1590/S0066-782X1999000700004 | |
dc.identifier.file | S0066-782X1999000700004.pdf | |
dc.identifier.issn | 0066-782X | |
dc.identifier.lattes | 1590971576309420 | |
dc.identifier.lattes | 0246391303241376 | |
dc.identifier.orcid | 0000-0002-0648-876X | |
dc.identifier.scielo | S0066-782X1999000700004 | |
dc.identifier.uri | http://hdl.handle.net/11449/11267 | |
dc.language.iso | eng | |
dc.publisher | Sociedade Brasileira de Cardiologia (SBC) | |
dc.relation.ispartof | Arquivos Brasileiros de Cardiologia | |
dc.relation.ispartofjcr | 1.318 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | SciELO | |
dc.subject | Frank-Starling mechanism | en |
dc.subject | dP/dt | en |
dc.subject | ventricular function | en |
dc.title | Influence of the elevation of the left ventricular diastolic pressure on the values of the first temporal derivative of the ventricular pressure (dP/dt) | en |
dc.type | Artigo | |
unesp.author.lattes | 1590971576309420 | |
unesp.author.lattes | 0246391303241376[3] | |
unesp.author.orcid | 0000-0002-0648-876X[3] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Biociências, Botucatu | pt |
unesp.campus | Universidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatu | pt |
unesp.department | Clínica Médica - FMB | pt |
unesp.department | Pediatria - FMB | pt |
unesp.department | Bioestatística - IBB | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- S0066-782X1999000700004.pdf
- Tamanho:
- 399.58 KB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: