Simultaneous Determination of Ba, Cr, Mo (Group 1), and Cu, Fe, Ni, and Pb (Group 2) in Commercial Fuel Ethanol by Graphite Furnace AAS

Nenhuma Miniatura disponível

Data

2008-11-01

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Perkin-elmer Corp

Tipo

Artigo

Direito de acesso

Acesso restrito

Resumo

The direct and simultaneous determination of Ba, Cr, and Mo (group 1) and of Cu, Fe, Ni, and Pb (group 2) in commercial fuel ethanol by graphite furnace atomic absorption spectrometry is proposed employing no chemical modifier (group 1) and W permanent modifier together with Pd(NO(3))(2) + Mg(NO(3))(2) conventional modifiers (group 2). For 20 mu l, injected volume, the calculated characteristic masses were 65 pg Ba, 3 pg Cr, 13 pg Cu, 10 pg Fe, 43 pg Mo, 50 pg Ni, and 35 pg Pb. The limits of detection (LOD) were 0.6 mu g L(-1) Ba, 0.1 mu g L(-1) Cr, 0.6 mu g L(-1) Cu, 1.8 mu g L(-1) Fe, 0.2 mu g L(-1) Mo, 0.4 mu g L(-1) Ni, and 0.6 mu g L(-1) Pb. Accuracy was checked after the analysis of 10 commercial fuel ethanol samples. The recoveries of Ba, Cr, Cu, Fe, Mo, Ni, and Pb added to the fuel ethanol samples ranged from 100-123%, 84-123%, 85-99%, 90-117%, 81-102%, 89-119%, and 84-114%, and the relative standard deviations (n = 12) were 1.8%, 0.9%, 4.2%, 7.6%, 3.8%, 1.7%, and 2.0%, respectively. The useful lifetimes of the untreated and pretreated tubes were around 300 and 600 firings, respectively.