Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2024 a 5 de janeiro de 2025.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

 

Assessment of critical velocity in track and treadmill: Physiological profiles and relationship with 3000-meter performance

dc.contributor.authorMassini, Danilo Alexandre [UNESP]
dc.contributor.authorCaritá, Renato Aparecido [UNESP]
dc.contributor.authorSiqueira, Leandro Oliveira da Cruz [UNESP]
dc.contributor.authorSimionato, Astor Reis [UNESP]
dc.contributor.authorDenadai, Benedito Sérgio [UNESP]
dc.contributor.authorFilho, Dalton Muller Pessôa [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2019-10-06T17:05:23Z
dc.date.available2019-10-06T17:05:23Z
dc.date.issued2018-01-01
dc.description.abstractThe present study aiming to verify the interference of different conditions (treadmill vs. track) on critical velocity (CV) values, as well as on the correlation to the 3000-meter performance (v3000m), and thus infer about the specificity of each values as training parameter for this distance. Seven runners (15.3±1.4 years) were submitted to a maximal progressive test (1.0 km×h -1 increments per minute until exhaustion) to assess VȮ 2 max and maximal aerobic velocity (vVȮ 2 max). Subsequently, CV was estimated from three running performances at each test condition, with exercise intensities adjusted for different time limits (t Lim ) at 900, 2100 and 3300 meters in track or at 90, 95 and 115% of vVO 2 max in treadmill. From linear adjustments, using stepwise method, CV was assessed on treadmill (CV TREADMILL ) and track (CV TRACK ), and both compared by the Mann-Whitney test.The sample-adjusted dispersion coefficient (R 2 adj ) analyzed the variance of v3000m with CV TRACK , CV TREADMILL and vVȮ 2 max. In all analyses, significance was set at P≤0.05. In progressive test, VȮ 2 max reached 54.2±5.2 mLO 2 ×kg -1 ×min -1 and vVȮ 2 max reached 16.8±1.9 km×h -1 . No differences were observed between CV TREADMILL and CV TRACK (14.0±1.8 vs. 12.3±3.2 km×h -1 , P=0.46). Correlations were observed for v3000m with CV TREADMILL (R 2 adj ~0.94), CV TRACK (R 2 adj ~0.99) and vVȮ 2 max (R 2 adj ~0.90), all showing P=0.001. It could be concluded that no influence was observe on the ability to achieve identical CV values from different assessment conditions. The correlation to the v3000 meters suggested better specificity of CV TRACK than CV TREADMILL for training prescription and performance control.en
dc.description.affiliationSão Paulo State University (UNESP)
dc.description.affiliationSão Paulo State University (UNESP) Institute of Biosciences
dc.description.affiliationSão Paulo State University (UNESP) College of Sciences
dc.description.affiliationUnespSão Paulo State University (UNESP)
dc.description.affiliationUnespSão Paulo State University (UNESP) Institute of Biosciences
dc.description.affiliationUnespSão Paulo State University (UNESP) College of Sciences
dc.format.extent432-444
dc.identifierhttp://dx.doi.org/10.5007/1980-0037.2018v20n5p432
dc.identifier.citationRevista Brasileira de Cineantropometria e Desempenho Humano, v. 20, n. 5, p. 432-444, 2018.
dc.identifier.doi10.5007/1980-0037.2018v20n5p432
dc.identifier.fileS1980-00372018000500432.pdf
dc.identifier.issn1980-0037
dc.identifier.issn1415-8426
dc.identifier.scieloS1980-00372018000500432
dc.identifier.scopus2-s2.0-85062964952
dc.identifier.urihttp://hdl.handle.net/11449/190194
dc.language.isoeng
dc.relation.ispartofRevista Brasileira de Cineantropometria e Desempenho Humano
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectAthletic performance
dc.subjectExercise test
dc.subjectExercise tolerance
dc.subjectOxygen uptake
dc.subjectTrack and field
dc.titleAssessment of critical velocity in track and treadmill: Physiological profiles and relationship with 3000-meter performanceen
dc.titleAvaliação da velocidade crítica de corrida em pista e esteira: Perfis fisiológicos e relações com o desempenho em 3000 metrospt
dc.typeArtigo
unesp.author.lattes1907479250833033[5]
unesp.author.orcid0000-0003-0775-1889[5]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Biociências, Rio Claropt
unesp.departmentEducação Física - IBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1980-00372018000500432.pdf
Tamanho:
856.07 KB
Formato:
Adobe Portable Document Format