Publicação: Direct determination of Al, As, Cu, Fe, Mn, and Ni in fuel ethanol by simultaneous GFAAS using integrated platforms pretreated with W-Rh permanent modifier together with Pd plus Mg modifier
dc.contributor.author | de Oliveira, A. P. | |
dc.contributor.author | de Moraes, M. | |
dc.contributor.author | Neto, JAG | |
dc.contributor.author | Lima, E. C. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal do Rio Grande do Sul (UFRGS) | |
dc.date.accessioned | 2014-05-20T15:25:38Z | |
dc.date.available | 2014-05-20T15:25:38Z | |
dc.date.issued | 2002-11-01 | |
dc.description.abstract | A method is proposed for the simultaneous determination of Al, As, Cu, Fe, Mn, and Ni in fuel ethanol by electrothermal atomic absorption spectrometry (ETAAS) using W-Rh permanent modifier together with Pd(NO3)(2) + Mg(NO3)(2) conventional modifier. The integrated platform of a transversely heated graphite atomizer (THGA) was treated with tungsten, followed by rhodium, forming a deposit containing 250 mug W + 200 mug Rh. A 500-muL, volume of fuel ethanol was diluted with 500 muL, of 0.14 mol L-1 HNO3 in an autosampler cup of the spectrometer. Then, 20 muL, of the diluted ethanol was introduced into the pretreated graphite platform followed by the introduction of 5 mug Pd(NO3)(2) + 3 mug Mg(NO3)(2). The injection of this modifier was required to improve arsenic and iron recoveries in fuel ethanol. Calibrations were carried out using multi-element reference solutions prepared in diluted ethanol (1 + 1, v/v) acidified to 0. 14 mol L-1 HNO3. The pyrolysis and atomization temperatures of the heating program were 1200degreesC and 2200degreesC, respectively, which were obtained with multielement reference solutions in acidic diluted ethanol (1 + 1, v/v; 0. 14 mol L-1 HNO3). The characteristic masses for the simultaneous determination in ethanol fuel were 78 pg Al, 33 pg As, 10 pg Cu, 14 pg Fe, 7 pg Mn, and 24 pg Ni. The lifetime of the pretreated tube was about 700 firings. The detection limits (D.L.) were 1.9 mug L-1 Al, 2.9 mug L-1 As, 0.57 mug L-1.Cu, 1.3 mug L-1 Fe, 0.40 mug L-1 Mn, and 1.3 mug L-1 Ni. The relative standard deviations (n = 12) were 4%, 4%, 3%, 1.5%, 1.2%, and 2.2% for Al, As, Cu, Fe, Mn, and Ni, respectively. The recoveries of Al, As, Cu, Fe, Mn, and Ni added to the fuel ethanol samples varied from 81% to 95%, 80% to 98%, 97% to 109%, 85% to 107%, 98% to 106% and 97% to 103%, respectively. Accuracy was checked for the Al, As, Cu, Fe, Mn, and Ni determination in 10 samples purchased at a local gas station in Araraquara-SP City, Brazil. A paired t-test showed that at the 95% confidence level the results were in agreement with those obtained by single-element ETAAS. | en |
dc.description.affiliation | Univ Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil | |
dc.description.affiliation | Univ Fed Rio Grande Sul, Dept Quim Analit, BR-91501970 Porto Alegre, RS, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil | |
dc.format.extent | 190-195 | |
dc.identifier.citation | Atomic Spectroscopy. Norwalk: Perkin-elmer Corp, v. 23, n. 6, p. 190-195, 2002. | |
dc.identifier.issn | 0195-5373 | |
dc.identifier.uri | http://hdl.handle.net/11449/36006 | |
dc.identifier.wos | WOS:000180459900003 | |
dc.language.iso | eng | |
dc.publisher | Perkin-elmer Corp | |
dc.relation.ispartof | Atomic Spectroscopy | |
dc.relation.ispartofjcr | 1.123 | |
dc.relation.ispartofsjr | 0,327 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | Direct determination of Al, As, Cu, Fe, Mn, and Ni in fuel ethanol by simultaneous GFAAS using integrated platforms pretreated with W-Rh permanent modifier together with Pd plus Mg modifier | en |
dc.type | Artigo | |
dcterms.rightsHolder | Perkin-elmer Corp | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-8734-1208[4] |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: