Use of FIA systems for on-line dilution in multielement determination by ICP-MS

dc.contributor.authorNeto, JAG
dc.contributor.authorSilva, JBB
dc.contributor.authorSouza, I. G.
dc.contributor.authorCurtius, A. J.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)
dc.date.accessioned2014-05-20T15:29:17Z
dc.date.available2014-05-20T15:29:17Z
dc.date.issued1999-01-01
dc.description.abstractA flow-injection (FI) system to match concentrations was used as an auto-diluter in multielement determination by inductively coupled plasma-mass spectrometry (ICP-MS). The flow system comprised loop-based injection or a timed valve that introduced a variable sample volume info a spray chamber through a standard Meinhard nebulizer of an ICP-MS. Routinely analyzed samples such as water, plant, and steel were selected. The accuracy of multielement determination was checked against water standard reference material from the National Institute of Standards and Technology (1643d), plant standard reference material from the National Bureau of Standards (1572 citrus leaves), and steel standard reference material from the National Bureau of Standards (AISI 4340). The measuring system was calibrated with a multielement solution, yielding a linear plot with good precision [relative standard deviation (RSD) < 3%, n = 12]. The results were in agreement at a 95% confidence level with the certified values for the reference materials and also with those obtained by continuous aspiration and by (FI) with a discrete volume. (C) 1999 John Wiley & Sons, Inc.en
dc.description.affiliationUNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil
dc.description.affiliationUniv Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
dc.description.affiliationUnespUNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil
dc.format.extent240-247
dc.identifierhttp://dx.doi.org/10.1002/(SICI)1098-2728(1999)11:4<240
dc.identifier.citationLaboratory Robotics and Automation. New York: John Wiley & Sons Inc., v. 11, n. 4, p. 240-247, 1999.
dc.identifier.doi10.1002/(SICI)1098-2728(1999)11:4<240
dc.identifier.issn0895-7533
dc.identifier.urihttp://hdl.handle.net/11449/38891
dc.identifier.wosWOS:000081987700010
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofLaboratory Robotics and Automation
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleUse of FIA systems for on-line dilution in multielement determination by ICP-MSen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-Blackwell
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: