Effect of heat treatment on stainless steel orthodontic wires

Carregando...
Imagem de Miniatura

Data

2011-04-01

Autores

Cuoghi, Osmar Aparecido [UNESP]
Kasbergen, Geraldo Francisco
Santos, Paulo Henrique dos [UNESP]
Mendonça, Marcos Rogério de [UNESP]
Tondelli, Pedro Marcelo [UNESP]

Título da Revista

ISSN da Revista

Título de Volume

Editor

Sociedade Brasileira de Pesquisa Odontológica (SBPqO)

Resumo

This study evaluated the effect of heat treatment on CrNi stainless steel orthodontic archwires. Half of forty archwires of each thickness - 0.014 (0.35 mm), 0.016 (0.40 mm), 0.018 (0.45 mm) and 0.020 (0.50 mm) (totalling 160 archwires) - were subjected to heat treatment while the remainder were not. All of the archwires had their individual thickness measured in the anterior and posterior regions using AutoCad 2000 software before and after compressive and tensile strength testing. The data was statistically analysed utilising multivariance ANOVA at a 5% significance level. All archwires without heat treatment that were subjected to tensile strength testing presented with anterior opening, which was more accentuated in the 0.020 archwires. In the posterior region, the opening produced by the tensile force was more accentuated in the archwires without heat treatment. There was greater stability in the thermally treated archwires, especially those subjected to tensile strength testing, which indicates that the heat treatment of orthodontic archwires establishes a favourable and indispensable condition to preserve the intercanine width.

Descrição

Palavras-chave

Orthodontic Wires, Stainless Steel, Tooth Movement

Como citar

Brazilian Oral Research. Sociedade Brasileira de Pesquisa Odontológica , v. 25, n. 2, p. 128-134, 2011.