Radiopacity evaluation of root-end filling materials by digitization of images

Carregando...
Imagem de Miniatura

Data

2008-11-01

Autores

Tanomaru-Filho, Mario [UNESP]
da Silva, Guilherme Ferreira
Hungaro Duarte, Marco Antonio
Gonçalves, Marcelo [UNESP]
Guerreiro Tanomaru, Juliane Maria [UNESP]

Título da Revista

ISSN da Revista

Título de Volume

Editor

Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru

Resumo

The purpose of this study was to evaluate the radiopacity of 5 root-end filling materials (white MTA-Angelus, grey MTA-Angelus, IRM, Super EBA and Sealer 26). Five specimens (10 mm diameter X 1 mm thickness) were made from each material and radiographed next to an aluminum stepwedge varying in thickness from 2 to 16 mm. Radiographs were digitized and the radiopacity of the materials was compared to that of the aluminum stepwedge using VIXWIN 2000 software in millimeters of aluminum ( mm Al). Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. Radiopacity values varied from 3 mm Al to 5.9 mm Al. Sealer 26 and IRM presented the highest radiopacity values (p<0.05), while white/grey MTA and Super EBA presented the lowest radiopacity values (p<0.05). The tested root- end filling materials presented different radiopacities, white/grey MTA and Super EBA being the least radiopaque materials.

Descrição

Palavras-chave

Radiopacity, Retrograde obturation, Root canal filling materials, Radiology

Como citar