Preparation and characterization of alloys of the Ti–15Mo–Nb system for biomedical applications

Nenhuma Miniatura disponível

Data

2018-02-01

Autores

Martins Júnior, J. R.S. [UNESP]
Matos, A. A.
Oliveira, R. C.
Buzalaf, M. A.R.
Costa, I.
Rocha, L. A. [UNESP]
Grandini, C. R. [UNESP]

Título da Revista

ISSN da Revista

Título de Volume

Editor

Resumo

In the development of new metallic biomaterials, the Ti–15Mo alloy has great prominence because of its excellent corrosion resistance and good combination of mechanical properties. In this study, the element niobium was added to the Ti–15Mo alloy, forming the Ti–15Mo–Nb system for the purpose of improving their properties and promoting its application as a biomaterial. These alloys are very promising to use as biomedical implants, because they integrate a new class of titanium alloys without the presence of aluminum and vanadium, which may cause cytotoxic effects. The alloys were produced by arc-melting and characterized by density, X-ray diffraction, scanning electron microscopy, microhardness, elastic modulus, corrosion, and cytotoxicity assays. The developed alloys have β phase predominance (with bcc crystalline structure). The addition of niobium decreases the microhardness and elastic modulus, with values around 80 GPa, which is well below that of the metallic alloys used commercially for this type of application. Very low passive current densities were found for all alloys studied showing that the passive film on these alloys is highly protective. In vitro cytotoxicity tests revealed that the introduction of niobium did not cause cytotoxic effects in the studied alloys. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 639–648, 2018.

Descrição

Palavras-chave

biomaterials, corrosion, elastic modulus, Ti alloys

Como citar

Journal of Biomedical Materials Research - Part B Applied Biomaterials, v. 106, n. 2, p. 639-648, 2018.