Methods for determination of hexachlorobenzene and pentachlorophenol in soil samples

Nenhuma Miniatura disponível

Data

1998-08-01

Autores

Polese, L.
Ribeiro, M. L.

Título da Revista

ISSN da Revista

Título de Volume

Editor

Elsevier B.V.

Resumo

The efficiency of methods for the determination of hexachlorobenzene (HCB) and pentachlorophenol (PCP) in soil samples was evaluated. An on-line method was applied for HCB determination. Soil samples were transferred to chromatographic columns prepacked with alumina. The HCB elution was processed with n-hexane. The PCP was extracted from soil samples with n-hexane-acetone in an ultrasonic bath. After re-extraction with K2CO3 solution PCP was acetylated with acetic anhydride. The pentachlorophenyl acetate derivative was then extracted with n-hexane. The HCB and PCP derivative were analyzed by gas chromatography with electron capture detection (GC-ECD). Mean recoveries obtained from soil samples fortified at levels of 0.5; 4 and 20 ng g(-1) ranged from 91 to 100% for HCB, and for PCP, at levels of 10; 40 and 200 ng g(-1), ranged from 88 to 101%. These results demonstrated the efficiency of the proposed methods. (C) 1998 Elsevier B.V. B.V. All rights reserved.

Descrição

Palavras-chave

hexachlorobenzene, pentachlorophenol, soil, GC-ECD

Como citar

Talanta. Amsterdam: Elsevier B.V., v. 46, n. 5, p. 915-920, 1998.