Orthodontic brackets removal under shear and tensile bond strength resistance tests - a comparative test between light sources

Nenhuma Miniatura disponível

Data

2008-01-01

Autores

Silva, P. C. G. [UNESP]
Porto-Neto, S. T. [UNESP]
Lizarelli, R.
Bagnato, V S

Título da Revista

ISSN da Revista

Título de Volume

Editor

Wiley-v C H Verlag Gmbh

Resumo

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Descrição

Palavras-chave

lEDs, bracket, tensile, shear, bonding strength, fracture patterns

Como citar

Laser Physics Letters. Weinheim: Wiley-v C H Verlag Gmbh, v. 5, n. 3, p. 220-226, 2008.

Coleções