Use of gastric balloon manometry for estimation of intra-abdominal pressure in horses

dc.contributor.authorCanola, P. A. [UNESP]
dc.contributor.authorPerotta, J. H. [UNESP]
dc.contributor.authorLaskoski, L. M. [UNESP]
dc.contributor.authorEscobar, André [UNESP]
dc.contributor.authorMelo e Silva, C. A.
dc.contributor.authorCanola, J. C. [UNESP]
dc.contributor.authorJohnson, P. J.
dc.contributor.authorValadao, C. A. A. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de Brasília (UnB)
dc.contributor.institutionUniv Missouri
dc.date.accessioned2014-05-20T15:30:00Z
dc.date.available2014-05-20T15:30:00Z
dc.date.issued2011-11-01
dc.description.abstractReasons for performing study: Standing laparoscopic procedures, facilitated by abdominal insufflation with carbon dioxide, are being employed to an increasingly greater extent in horses. However, a sustained increase in abdominal pressure may be life-threatening. A practical method for intra-abdominal pressure (IAP) assessment is imperative. Although indirect methods for estimating IAP have been extensively studied in man, little work has been performed in veterinary medicine.Objectives: To investigate the utility of gastric manometry for purposes of evaluating IAP in horses.Methods: Gastric pressure (P(ga)) was estimated by balloon manometry in 8 healthy, mature horses, before and during a 30 min passive pneumoperitoneum induced by right paralumbar puncture. The balloon manometer was positioned within the gastric lumen and inflated using 2 separate volumes of air: 10 and 50 ml. P(ga) Gastric pressure was determined at baseline (0) and 5, 15 and 30 min after induction of passive pneumoperitoneum. Intra-abdominal pressure was measured directly by right paralumbar puncture using an 8 gauge needle at baseline and immediately following establishment of passive pneumoperitoneum.Results: Baseline IAP values were negative and increased (P <= 0.05) during development of passive pneumoperitoneum. However, recorded P(ga) measurements for both inflation volumes were positive before (baseline) and during the course of the passive pneumoperitoneum. Measured P(ga) values did not correlate with IAP at any time.Conclusions and potential relevance: Our results suggest that the indirect method used in human patients for estimating IAP by P(ga) is not applicable for horses.en
dc.description.affiliationSão Paulo State Univ, Vet Surg Grad Program, Sch Agr Sci & Vet Med, São Paulo, Brazil
dc.description.affiliationUniversidade de Brasilia (UnB), Physiol Resp Lab, BR-70910900 Brasilia, DF, Brazil
dc.description.affiliationSão Paulo State Univ, Dept Vet Clin & Surg, Sch Agr Sci & Vet Med, São Paulo, Brazil
dc.description.affiliationUniv Missouri, Dept Vet Med & Surg, Coll Vet Med, Columbia, MO 65211 USA
dc.description.affiliationUnespSão Paulo State Univ, Vet Surg Grad Program, Sch Agr Sci & Vet Med, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Vet Clin & Surg, Sch Agr Sci & Vet Med, São Paulo, Brazil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent714-720
dc.identifierhttp://dx.doi.org/10.1111/j.2042-3306.2010.00359.x
dc.identifier.citationEquine Veterinary Journal. Malden: Wiley-blackwell, v. 43, n. 6, p. 714-720, 2011.
dc.identifier.doi10.1111/j.2042-3306.2010.00359.x
dc.identifier.issn0425-1644
dc.identifier.lattes3144173608741010
dc.identifier.lattes3874036760952509
dc.identifier.orcid0000-0003-4354-6487
dc.identifier.urihttp://hdl.handle.net/11449/39464
dc.identifier.wosWOS:000296047200013
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofEquine Veterinary Journal
dc.relation.ispartofjcr2.022
dc.relation.ispartofsjr0,991
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectHorseen
dc.subjectIntra-abdominal hypertensionen
dc.subjectAbdominal Compartment syndromeen
dc.subjectPneumoperitoneumen
dc.subjectstomachen
dc.titleUse of gastric balloon manometry for estimation of intra-abdominal pressure in horsesen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
unesp.author.lattes3144173608741010
unesp.author.lattes3874036760952509[1]
unesp.author.lattes5566877625835272[8]
unesp.author.orcid0000-0003-4354-6487[1]
unesp.author.orcid0000-0001-5283-7310[8]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Ciências Agrárias e Veterinárias, Jaboticabalpt

Arquivos

Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: