Implant image quality in dental radiographs recorded using a customized imaging guide or a standard film holder

dc.contributor.authorSchropp, Lars
dc.contributor.authorStavropoulos, Andreas
dc.contributor.authorSpin-Neto, Rubens [UNESP]
dc.contributor.authorWenzel, Ann
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionAarhus University (AU)
dc.date.accessioned2013-09-30T18:31:52Z
dc.date.accessioned2014-05-20T13:45:25Z
dc.date.available2013-09-30T18:31:52Z
dc.date.available2014-05-20T13:45:25Z
dc.date.issued2012-01-01
dc.description.abstractObjective: To compare a customized imaging guide and a standard film holder for obtaining optimally projected intraoral radiographs of dental implants.Material and methods: Intraoral radiographs of four screw-type implants with different inclination placed in an upper or lower dental phantom model were recorded by 32 groups of examiners after a short instruction in the use of the RB-RB/LB-LB mnemonic rule. Half of the examiners recorded the images using a standard film holder and the other half used a customized imaging guide. Each radiograph was assessed under blinded conditions with regard to rendering of the implant threads and was assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable, and (4) hopeless.Results: For the upper jaw, the same number of exposures per implant were made to achieve an acceptable image (P = 0.86) by the standard film holder method (median = 2) and the imaging guide method (median = 2). For the lower jaw, medians for the imaging guide method and the film holder method were 1 and 2, respectively (P = 0.004). For the imaging guide method, the first exposure was rated as perfect/acceptable in 62% of the cases and for the film holder method in 41% of the cases (P = 0.013). After <= 2 exposures, 78% (imaging guide method) and 69% (film holder method) of the implant images were perfect/acceptable (P=0.23). The implant inclination did not have a major influence on the outcomes.Conclusion: Perfect or acceptable images were achieved after two exposures with the same frequency either using a customized imaging guide method or a standard film holder method. However, the use of a customized imaging guide method was overall significantly superior to a standard film holder method in terms of obtaining perfect or acceptable images with only one exposure.en
dc.description.affiliationAarhus Univ, Sch Dent, Dept Prosthet Dent, DK-8000 Aarhus C, Denmark
dc.description.affiliationAarhus Univ, Sch Dent, Dept Periodontol, DK-8000 Aarhus C, Denmark
dc.description.affiliationUNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Periodontol, São Paulo, Brazil
dc.description.affiliationAarhus Univ, Sch Dent, Dept Oral Radiol, DK-8000 Aarhus C, Denmark
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Periodontol, São Paulo, Brazil
dc.format.extent55-59
dc.identifierhttp://dx.doi.org/10.1111/j.1600-0501.2011.02180.x
dc.identifier.citationClinical Oral Implants Research. Malden: Wiley-blackwell, v. 23, n. 1, p. 55-59, 2012.
dc.identifier.doi10.1111/j.1600-0501.2011.02180.x
dc.identifier.issn0905-7161
dc.identifier.urihttp://hdl.handle.net/11449/15979
dc.identifier.wosWOS:000298548900009
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofClinical Oral Implants Research
dc.relation.ispartofjcr4.305
dc.relation.ispartofsjr2,462
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectdentalen
dc.subjectimaging guideen
dc.subjectimplanten
dc.subjectintraoralen
dc.subjectradiographyen
dc.titleImplant image quality in dental radiographs recorded using a customized imaging guide or a standard film holderen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
unesp.author.orcid0000-0003-4897-1554[1]
unesp.author.orcid0000-0002-9562-0610[3]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquarapt

Arquivos

Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: