Estudo in vitro para avaliação e validação de medidas lineares na tomografia computadorizada 3D cone beam comparadas às medidas do crânio in situ

dc.contributor.advisorAraújo, Adriano Marotta [UNESP]
dc.contributor.authorMatai , Caio Vinicius Bardi [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:29:12Z
dc.date.available2014-06-11T19:29:12Z
dc.date.issued2009-07-06
dc.description.abstractAs tomografias computadorizadas (TC) tridimensionais (3D) solucionaram em grande parte as inconveniências da sobreposição de acidentes anatômicos laterais comuns (dependendo da direção de incidência dos raios X) nas radiografias realizadas com o indivíduo em perfil. Também eliminou-se a sobreposição de imagens comuns a métodos radiográficos 2D. O propósito neste trabalho foi comparar a precisão das mensurações 3D na identificação de estruturas craniofaciais e ampliar o conhecimento da classe odontológica sobre o uso da Tomografia computadorizada 3D cone beam’ (TCCB) como ferramenta de auxílio no diagnóstico das estruturas faciais. Foram utilizados cinco crânios secos, pertencentes à Disciplina de Anatomia da Faculdade de Odontologia de São José dos Campos – UNESP. Os crânios foram fixados em relação central dos côndilos com máxima intercuspidação dos dentes. Todos os crânios apresentaram seus pontos cefalométricos demarcados com identificadores metálicos e escaneados no tomógrafo cone beam Newtom, sendo que todas as medidas lineares foram comparadas com as medidas in situ mensuradas com o auxílio do paquímetro digital. Após validação do erro do operador, os dados obtidos foram comparados e submetidos a estatística descritiva e à análise de Wilcoxon. Os resultados mostraram que 40% das medidas tiveram uma diferença menor que 0,16mm, 85% apresentaram acurácia abaixo do valor de 0,58mm e que menos de 3% das medidas tiveram diferença de valores acima de 1mm. O teste de Wilcoxon não encontrou nenhuma diferença estatisticamente significante entre os métodos. Concluímos que a TCCB é um método preciso para obtenção de medidas linear de estruturas do crânio quando comparada as mesmas mensurações realizadas in situ(AU)pt
dc.description.abstractThe three-dimensional (3D) computed tomography (CT) overcame many of the hassles of overlapping anatomical accidents common in lateral radiographs taken with the individual in profile. Also eliminated the overlap of images common to 2D radiographic methods. The purpose of this study was to compare the accuracy of 3D measurements in the identification of craniofacial structures and expanding the knowledge of the class on the use of dental computed tomography 3D cone beam (CBCT) as a tool to aid in the diagnosis of facial structures. The tests were in situ, on a five dry skulls, belonging to the Discipline of Anatomy, São José dos Campos Dental School- UNESP. The skulls were fixed on the central condyle with maximum intercuspation teeth. All of than had their skulls cephalometric points marked with metal identifiers and scanned with Newtom cone beam tomography. Linear measurements were compared with measures in situ measured using the digital caliper. After validation of operator error, the data were compared and subjected to descriptive statistics and analysis of Wilcoxon. The results showed that 40% have had a difference of less than 0.16 mm, 85% were below the accuracy of 0.58 mm and less than 3% of the difference in values were over 1 mm. The test of Wilcoxon found no statistically significant difference between the methods. We conclude that CBCT is a precise method for identifying and measuring the linear skull’s structures when compared the same measurements performed with digital caliper in situ(AU)en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent73 f. : il.
dc.identifier.aleph000605794
dc.identifier.capes33004145081P0
dc.identifier.citationMATAI , Caio Vinicius Bardi. Estudo in vitro para avaliação e validação de medidas lineares na tomografia computadorizada 3D cone beam comparadas às medidas do crânio in situ. 2009. 73 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Odontologia de São José dos Campos., 2009.
dc.identifier.filematai_cvb_me_sjc.pdf
dc.identifier.urihttp://hdl.handle.net/11449/98013
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso aberto
dc.sourceAleph
dc.subjectTomografiapt
dc.subjectCefalometriapt
dc.subjectCranio - Radiografiapt
dc.subjectThree-dimensional computed tomographyen
dc.titleEstudo in vitro para avaliação e validação de medidas lineares na tomografia computadorizada 3D cone beam comparadas às medidas do crânio in situpt
dc.typeDissertação de mestrado
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.graduateProgramBiopatologia Bucal - ICTpt
unesp.knowledgeAreaRadiologia odontológicapt
unesp.researchAreaUso e aplicações de equipamentos, materiais e técnicas radiográficas em Odontologiapt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
matai_cvb_me_sjc.pdf
Tamanho:
1.17 MB
Formato:
Adobe Portable Document Format