In situ and in vitro comparison of laser fluorescence with visual inspection in detecting occlusal caries lesions

dc.contributor.authorde Paula, Andreia Bolzan
dc.contributor.authorDuarte Bonini Campos, Juliana Alvares [UNESP]
dc.contributor.authorDiniz, Michele Baffi [UNESP]
dc.contributor.authorHebling, Josimeri [UNESP]
dc.contributor.authorRodrigues, Jonas Almeida
dc.contributor.institutionUniv Bern
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:33:56Z
dc.date.accessioned2014-05-20T13:44:49Z
dc.date.available2013-09-30T18:33:56Z
dc.date.available2014-05-20T13:44:49Z
dc.date.issued2011-01-01
dc.description.abstractThe aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.en
dc.description.affiliationUniv Bern, Sch Dent Med, Dept Prevent Restorat & Pediat Dent, CH-3010 Bern, Switzerland
dc.description.affiliationState Univ Campinas UNICAMP, Dept Dent Mat, Piracicaba Sch Dent, Piracicaba, SP, Brazil
dc.description.affiliationSão Paulo State Univ UNESP, Dept Social Dent, Araraquara Sch Dent, Araraquara, SP, Brazil
dc.description.affiliationSão Paulo State Univ UNESP, Dept Pediat Dent, Araraquara Sch Dent, Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Dept Social Dent, Araraquara Sch Dent, Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Dept Pediat Dent, Araraquara Sch Dent, Araraquara, SP, Brazil
dc.format.extent1-5
dc.identifierhttp://dx.doi.org/10.1007/s10103-009-0731-y
dc.identifier.citationLasers In Medical Science. London: Springer London Ltd, v. 26, n. 1, p. 1-5, 2011.
dc.identifier.doi10.1007/s10103-009-0731-y
dc.identifier.issn0268-8921
dc.identifier.urihttp://hdl.handle.net/11449/15719
dc.identifier.wosWOS:000284274100001
dc.language.isoeng
dc.publisherSpringer London Ltd
dc.relation.ispartofLasers in Medical Science
dc.relation.ispartofjcr1.949
dc.relation.ispartofsjr0,713
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectLaser fluorescenceen
dc.subjectDIAGNOdenten
dc.subjectCaries detectionen
dc.subjectVisual inspectionen
dc.subjectOcclusal cariesen
dc.titleIn situ and in vitro comparison of laser fluorescence with visual inspection in detecting occlusal caries lesionsen
dc.typeResumo
dcterms.licensehttp://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0
dcterms.rightsHolderSpringer London Ltd
unesp.author.orcid0000-0001-8887-2329[5]
unesp.author.orcid0000-0002-0693-2162[3]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquarapt

Arquivos

Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: