Avaliação da limpeza de CDtrodo construídos a partir de CD de ouro gravável/fita adesiva de galvanoplastia

dc.contributor.authorFoguel, M. V. [UNESP]
dc.contributor.authorUliana, C. V. [UNESP]
dc.contributor.authorTomaz, P. R.U. [UNESP]
dc.contributor.authorMarques, P. R. B. Oliveira [UNESP]
dc.contributor.authorYamanaka, H. [UNESP]
dc.contributor.authorFerreira, A. A. Pupim [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-28T19:45:47Z
dc.date.available2022-04-28T19:45:47Z
dc.date.issued2009-01-01
dc.description.abstractGold electrodes are widely used in electrochemistry and electroanalytical chemistry, due to the high purity, broad range of work potential as well as the possibility to control and modify the surface. On this work construction and cleaning of electrodes from gold recordables compact discs (CD-Rs), namely CDtrodes, are described. The CDs was submitted to the action of concentrated HNO3 in order to remove the protection layer and to expose the metallic layer; the electrode area was delimited by using galvanoplasty tape. The literature has been published many articles on CDtrode focused on the application but not on the cleaning; there is no register on galvanoplasty tape to define electrode area. Several methods for gold surface cleaning after attack of HNO3 were investigated, such as application of fixed potential in NaCl solution, successive scans in H2SO4 and ultrasound application, and best results were obtained in H2SO4 solution. This electrode material is interesting due to the performance comparable to the commercial electrodes, besides great versatility and low cost.en
dc.description.affiliationUNESP - Universidade Estadual Paulista Instituto de Química, Campus de Araraquara. CP 355, SP
dc.description.affiliationUnespUNESP - Universidade Estadual Paulista Instituto de Química, Campus de Araraquara. CP 355, SP
dc.format.extent59-66
dc.identifierhttp://dx.doi.org/10.26850/1678-4618EQJ.V34.2.2009.P59-66
dc.identifier.citationEcletica Quimica, v. 34, n. 2, p. 59-66, 2009.
dc.identifier.doi10.26850/1678-4618EQJ.V34.2.2009.P59-66
dc.identifier.issn1678-4618
dc.identifier.issn0100-4670
dc.identifier.scopus2-s2.0-85116836202
dc.identifier.urihttp://hdl.handle.net/11449/222610
dc.language.isopor
dc.relation.ispartofEcletica Quimica
dc.sourceScopus
dc.subjectCDtrode, CD-R electrodes
dc.subjectCyclic voltammetry
dc.subjectGold surface cleaning
dc.titleAvaliação da limpeza de CDtrodo construídos a partir de CD de ouro gravável/fita adesiva de galvanoplastiapt
dc.title.alternativeEvaluation of the CDtrode cleaning constructed from gold recordable CD/galvanoplasty tapeen
dc.typeArtigo

Arquivos

Coleções