Evaluation of dimensional change and detail reproduction in silicones for facial prostheses.

dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorPesqueira, Aldieris Alves [UNESP]
dc.contributor.authorSantos, Daniela Micheline dos [UNESP]
dc.contributor.authorAntenucci, Rosse Mary Falcón
dc.contributor.authorRibeiro, Paula do Prado
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:23:46Z
dc.date.available2014-05-27T11:23:46Z
dc.date.issued2008-12-01
dc.description.abstractThe aim of this study was to evaluate the dimensional stability and detail reproduction of two silicones used for facial prosthesis, under the influence of chemical disinfection and storage time. Twenty-eight test specimens were obtained, half made of Silastic MDX 4-4210 silicone, and the other half of Silastic 732 RTV silicone. The test specimens were divided into 4 groups: Silastic 732 RTV and Silastic MDX 4-4210, with disinfection 3 times a week with Efferdent and without disinfection. Dimensional change was analyzed using an electronic comparison microscope and detail reproduction was observed under a stereo microscope, immediately and 2 months after the test specimens were made. Once the results were obtained, an analisis of variance (ANOVA) was applied, followed by the Tukey's Test with 1% confidence. The storage time factor had a statistical influence on dimensional stability: Silastic MDX 4-4210 had less contraction than Silastic 732 RTV. Chemical disinfection did not significantly alter the dimensional stability of the materials used. Regarding detail reproduction, no alteration of values was observed in any of the materials analyzed, regardless of storage period or disinfection.en
dc.format.extent85-88
dc.identifierhttp://www.actaodontologicalat.com/archivo/v21n1/fulltext/articulo13.pdf
dc.identifier.citationActa odontológica latinoamericana : AOL, v. 21, n. 1, p. 85-88, 2008.
dc.identifier.issn0326-4815
dc.identifier.lattes9719883814872582
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.scopus2-s2.0-58149147079
dc.identifier.urihttp://hdl.handle.net/11449/70779
dc.language.isoeng
dc.relation.ispartofActa Odontológica Latinoamericana (AOL)
dc.relation.ispartofsjr0,264
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectdisinfectant agent
dc.subjectsilastic
dc.subjectchemistry
dc.subjectcomparative study
dc.subjectdental care
dc.subjectevaluation
dc.subjectmaterials testing
dc.subjectmaxillofacial prosthesis
dc.subjecttime
dc.subjectDental Disinfectants
dc.subjectDental Stress Analysis
dc.subjectMaterials Testing
dc.subjectMaxillofacial Prosthesis
dc.subjectSilicone Elastomers
dc.subjectTime Factors
dc.titleEvaluation of dimensional change and detail reproduction in silicones for facial prostheses.en
dc.typeArtigo
dcterms.licensehttp://www.actaodontologicalat.com/peditorial.html
unesp.author.lattes9719883814872582
unesp.author.lattes2336450644149867[2]
unesp.author.orcid0000-0002-3800-3050[1]
unesp.author.orcid0000-0003-3020-5253[2]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araçatubapt

Arquivos